FlexiDome IP
Troubleshooting | en
99
Bosch Security Systems
Operating Instructions
V 1.0 | 2006.12
The unit does not
report an alarm.
Alarm source is not
selected.
Select possible alarm sources on
the
Alarm sources
configuration
page.
No alarm response speci-
fied.
Specify the desired alarm
response on the
Alarm connec-
tions
configuration page, if neces-
sary change the IP address.
The unit is not opera-
tional after firmware
upload.
Power failure during pro-
gramming by the update file.
Have the unit checked by Cus-
tomer Service and replace if neces-
sary.
Incorrect update file.
Enter the IP address followed by
/
main.htm
in your web browser
and repeat the upload.
No LUNs are dis-
played after connect-
ing to the iSCSI
server.
iSCSI server configuration
has incorrect LUN mapping.
Check iSCSI server configuration
and reconnect.
LUN FAIL is dis-
played under a node
after connecting to
the iSCSI server.
The LUN list could not be
accessed because it was
assigned to the wrong net-
work interface.
Check iSCSI server configuration
and reconnect.
LUN mapping not
possible.
The iSCSI system does not
support the use of initiator
identification.
Delete the identity on the iSCSI-
parameter configuration page.
Malfunction
Possible causes
Solution