FlexiDome IP
Configuration via the browser | en
83
Bosch Security Systems
Operating Instructions
V 1.0 | 2006.12
If you want to limit connections to SSL encryption, you must set
the
Off
option in the HTTP browser port, the RCP+ port, and
Telnet support. This deactivates all unencrypted connections
allowing connections on the HTTPS port only.
RCP+ port 1756
Activating RCP+ port 1756 allows unencrypted connections on
this port. If you want to allow only encrypted connections, you
must set the
Off
option to deactivate the port.
Telnet support
Activating Telenet support allows unencrypted connections on
this port. If you want to allow only encrypted connections, you
must set the
Off
option to deactivate telnet support, making
telnet connections impossible.
Ethernet link type
If the camera is connected to the network via a switch, both
devices must have the same preset network connection type. If
necessary, ask your network administrator what value the asso-
ciated switch is set to.
Choose Auto for an autosensing network connection. If neces-
sary you can set the value to 10 or 100 MBit/s for either full or
half-duplex mode (FD or HD).
1. SNMP host address / 2. SNMP host address
The camera supports the SNMP V2 (Simple Network Manage-
ment Protocol) for managing and monitoring network compo-
i
NOTICE!
You can configure and activate encryption for media data
(video, audio, metadata) on the
Encryption
page (see
“Encryption” on page 86).
i
NOTICE!
Malfunctions can occur (for example image faults) if the
network capacity is not sufficient for transmission of the
maximum data rate generated by the camera.