FLEXIDOME indoor 5100i (IR) | FLEXIDOME
outdoor 5100i (IR)
Configuration | en
15
Bosch Security Systems B.V.
User manual
11-2022 | V02 | F.01U.394.427
Note
: It is important that the date/time is correct for recording. An incorrect date/time setting
could prevent correct recording.
Device time zone
Select the time zone in which the system is located.
Daylight saving time
The internal clock can switch automatically between normal and daylight saving time (DST).
The unit already contains the data for DST switch-overs for many years in advance. If the date,
time and zone have been set up correctly, a DST table is automatically created.
If you decide to create alternative daylight saving time dates by editing the table, note that
values occur in linked pairs (DST start and end dates).
First, check the time zone setting. If it is not correct, select the appropriate time zone and
click
Set
.
1.
Click
Details
to edit the DST table.
2.
Click
Generate
to fill the table with the preset values from the unit.
3.
Click one of the entries in the table to make changes. The entry is highlighted.
4.
Click
Delete
to remove the entry from the table.
5.
Choose other values from the list boxes under the table, to change the selected entry.
Changes are immediate.
6.
If there are empty lines at the bottom of the table, for example after deletions, add new
data by marking the row and selecting values from the list boxes.
7.
When finished, click
OK
to save and activate the table.
Time server address
The camera can receive the time signal from time server using various time server protocols,
and then use it to set the internal clock. The unit polls the time signal automatically once every
minute.
Enter the IP address of a time server here.
You can choose to have the DHCP server give a time server date by selecting the
Overwrite by
DHCP
option.
Time server type
Select the protocol that is supported by the selected time server.
–
Select
Time protocol
if the server uses the protocol RFC 868.
–
The
SNTP protocol
supports a high level of accuracy and is required for special
applications and subsequent function extensions.
–
Select
TLS protocol
if the server uses the RFC 5246 protocol.
–
Select
Off
to disable the time server.
Click
Set
to apply the changes.
4.2
Web interface
4.2.1
Appearance
You can adapt the appearance of the web interface and change the website language to meet
your requirements.
Website language
Select the language for the user interface.
The default language is English.
After setting the new language, the page refreshes automatically. The GUI now displays field
names and options, as well as OSD messages, in the selected language.