Figure 5.1: Cable Connection Terminators
1
Terminals for incoming power and telemetry cables
2
Internal illuminator use. DO NOT connect any cables to these terminals.
3
Power In (12–24 VDC/12–24 VAC)
4
Power In (12–24 VDC/12–24 VAC)
5
Telemetry (for remote illuminator control)
6
Telemetry (for remote illuminator control)
!
Caution!
Connections to the terminal block must be made to the terminals on the left side. Do not
make connections to the terminals on the right side of the block.
To make connections, follow these steps.
1. Loosen the set screws on the rear end cap using the supplied hex key. Loosen the rear end
cap using the multi-use tool. To prevent damage to the o-ring, for every half turn
counterclockwise turn back one quarter-turn clockwise.
Note: To prevent damage to the cap threads, take care not to drop the end caps.
Figure 5.2: Removal of end cap with multi-use tool
2. Unscrew the rear end cap by hand. Set the cap aside.
3. Feed power (and, if used, telemetry) cables through any one of the four 3/4-in. conduit
entries.
4. Connect one lead of the power cable to terminal 3 and the other lead to terminal 4.
Note: The power in terminals are polarity insensitive.
20
en | Connections
EX65 Explosion-Protected Illuminator
2016.03 | 1.0 | F.01U.321.732
Installation Manual
Bosch Security Systems