Troubleshooting
Illuminator Operation
The following table is intended to help you identify the causes of malfunctions and correct
them when possible.
Issue
Possible Solution
Fuse blows
–
Check the fuse rating.
–
Check for shorting between the housing and the input power
wires.
Cannot tell if LEDs
are ON
LEDs will have a faint red glow when ON. To check:
–
Aim the LEDs directly at an IR sensitive camera, or
–
Wait for the LEDs to warm up (two minutes).
LEDs are not ON
–
Cover the photocell to activate power to the LEDs (up to 30
seconds delay for activation).
–
Adjust the photocell sensitivity control. See Configuration, page
22.
–
Adjust power to the LEDs.
LEDs do not turn
OFF when sufficient
ambient light is
present
–
Make sure the photocell is not covered or hidden behind any
object.
–
Adjust the photocell sensitivity control. See Configuration, page
22. The LEDs remain ON or OFF if the adjustment is at full turn.
LEDs oscillating ON
and OFF
–
Adjust the photocell sensitivity control. See Configuration, page
22.
–
Remove any objects in front of the LEDs that are causing
reflections back to the photocell sensor.
8