DIVAR IP 6000 (3U)
System overview | en
15
Bosch Sicherheitssysteme GmbH
Installation Manual
2016.08 | V2.1 | DOC
3
1x serial port
4
1x network port for BMC (Baseboard
Management Controller) connection
and IPMI (Intelligent Platform
Management Interface) monitoring
5
4 USB ports
(2x USB 2.0 and 2x USB 3.0)
6
2x network ports for data transmission
(teamed)
Note:
Do not change the teaming
mode!
7
1x VGA display output (do not use!)
3.3.1
Control panel buttons
There are two push-buttons located on the front of the chassis. These are (in order from left
to right) a reset button and a power on/off button.
–
Reset
: The reset button is used to reboot the system.
–
Power:
The main power switch is used to apply or remove power from the power
supply to the system. Turning off system power with this button removes the main power
but keeps standby power supplied to the system.
Therefore, you must unplug system
before servicing.
3.3.2
Control panel LEDs
The control panel located on the front of the chassis has LEDs to provide you with critical
information related to different parts of the system. This section explains what each LED
indicates when illuminated.
–
Power failure
: A flashing LED indicates a power failure in the power supply.
–
Displays the system status.
System status
Description
Continously on and red
An overheat condition has occurred. (This may be caused
by cable congestion.)
Blinking red (1 Hz)
Fan failure: check for an inoperative fan.
Blinking red (0.25 Hz)
Power failure: check for an inoperative power supply.
Solid blue
Local UID has been activated. Use this function to locate
the unit in a rack environment.
Blinking blue (300 msec)
Remote UID has been activated. Use this function to locate
the unit from a remote location.
–
Overheat/fan fail
: A flashing LED indicates a fan failure.