1 689 989 087
2018-07-24
|
Robert Bosch GmbH
Initial startup | CRI/CRIN 848H | 71
en
4.6
Electrical connection of clamping
device
4.6.1
EPS 708
¶
Connect the trigger electronics by way of the con-
necting cable 1 684 463 698 (scope of delivery of
EPS 708) to connection X23 in the test area of the
EPS 708.
458847-3
6_Pal
Fig. 35: Connection of trigger electronics
4.6.2
EPS 815
1.
Join connecting cable (Fig. 36, item 1) 1 684 462 298
to X4 terminal of the control electronics.
2.
Connect voltage supply cable (Fig. 36, item 2)
1 684 463 504 to X2 terminal.
3.
Connect voltage supply cable (Fig. 36, item 3)
1 684 463 503 to X1 terminal.
458847-37_Pal
1
2
3
Fig. 36: Control electronics connection
1 RS 232 connecting cable
2 Voltage supply cable (-) 1 684 463 504
3 Voltage supply cable (+) 1 684 463 503
Содержание CRI 848H