Maintenance SCT 410 | SCT / CCT / EL | 47
en
9.
Compare the spirit level values on the VAS board to
the spirit level values on the precision measuring bar.
10.
If the spirit level values differ from one another,
realign the top end stops (see 1 690 386 065, sec.
"4.7 Installing the upper end stops") until the spirit
level values are the same.
Measure in case of damage
¶
Replace the end stops.
6.2.2
Checking the mounts
1
2
3
3
4
4512002-75_shd
Abb. 53: Front view of mounts
1 Retainer bushing
2 Profile
3 Mounting pins
4 Arresting cable
1.
Inspect the retainer bushing for visible flaws and
damage.
2.
Check the retainer bushing (Abb. 53, item 1) for
ease of movement.
3.
Check the profile (Abb. 53, item 2) for ease of mo-
vement.
4.
Check the height of the mounting pins (Abb. 53, item 3).
!
Height of the mounting pins: 2.5 mm +/- 0.5 mm
5.
Inspect the arresting cable (Abb. 53, item 4) for
damage; replace if necessary.
6.
Clean the magnets.
Measure in case of damage
¶
Replace the arresting cable.
¶
Replace the mount.
6.2.3
Checking the position indicator
¶
Inspect the position indicator for visible flaws and
damage.
Measure in case of damage
¶
Replace the position indicator.
Inspect the blue pointer:
1.
Using a tape measure, measure from the tip of the
blue pointer to the floor and note the value.
2.
Attach the calibration board to the precision measu-
ring bar.
3.
Measure from the middle of the calibration board to
the floor and compare to the previously noted value.
The measured values must not differ from one
another by more than 5 mm.
4.
If the value differs by more than the allowed amount,
readjust the position indicator.
Check the red pointer "SCT 2" (measurement bay with
no offset):
1.
Move the DAS 800/1000 (VAS 6430) to the lowest
position.
2.
Using a tape measure, measure from the tip of the
blue pointer to the floor.
The measured value must be 850 mm.
3.
If the value differs by more than the allowed amount,
readjust the pointer "SCT 1".
Check the red pointer "SCT 1" (measurement bay with
offset):
1.
Measure and note the offset value for the measure-
ment bay.
2.
The offset value measured must correspond to the
position of the red pointer "SCT 1".
3.
If the value differs by more than the allowed amount,
readjust the pointer "SCT 2".
6.2.4
Checking the tape measure holder
1.
Inspect the tape measure holder for visible flaws
and damage.
2.
Inspect the rotating element for deformation and
check for ease of movement.
Measure in case of damage
¶
Replace the tape measure holder.
7. Maintenance SCT 410
!
The standard components must be inspected before
carrying out maintenance on the SCT 410 (see sec. 4).
7.1
Components
7.1.1
Checking the socket pin
1.
Inspect the socket pin for visible flaws and damage.
2.
Check that the socket pin functions properly.
3.
Oil the socket pin.
7.1.2
Check the angle mounting bracket and clamp
1.
Inspect the angle mounting bracket and clamp for
visible flaws and damage.
2.
Check the guide hole with socket pin for ease of
movement.