5.2.5
Adjustment beam
1.
Grease the threads of the wing screws.
2.
Inspect the adjustment beam for visible flaws.
3.
Inspect sealing paint for damage.
4.
Check the bushings with the aid of the limit plug
gauge 15 H7.
4512001-26_shd
Abb. 39: Adjustment beam
5.2.6
Checking the reference boards
1.
Inspect the reference board for visible flaws.
2.
Inspect the sealing paint on the fastener for damage.
4512001-27_shd
Abb. 40: Front reference board
4512001-28_shd
1
Abb. 41: Rear reference board
1 Sealing paint on the fastener
3.
Move the adjustment beam to the transport position
(Abb. 30, item 4.10).
4.
Mount the reference board vertically on the adjust-
ment beam.
5.
Using the positioning feet, level the calibration and
adjustment device on the base plate with the aid of
the spirit levels on the L-bracket (Abb. 23, item 2 and
item 3).
6.
Position the P-Assist S5 at a distance of 3000 mm.
Align the P-Assist S5 with position A (scale mark 25)
on the reference board.
The laser beam is reflected.
7.
Position the test board at the height of the P-Assists
S5, but offset.
The reflected laser beam marks the test board.
8.
Using the reflected laser beam, align the test board
with the 0-point and fasten in place.
A
B
C
1
2
3
4
4512001-29_shd
3000 m
m
3000 mm
Abb. 42: Laser beam reflected on reference board and projected
onto test board
1 Transport position
2 Test board
3 P-Assist S5
4 Reference board
9.
Remove the reference board and interchange with
opposite reference board (exchange) without chan-
ging the position of the adjustment beam, P-Assist
S5 and test board and test board.
The interchanged reference board reflects the la-
ser beam onto the test board.
1
1
2
3
4512001-30_shd
Abb. 43: Interchanging the reference boards