8
en | System overview
Conettix Plug-in Communicator Interfaces
2017.10 | 09 | F.01U.300.740
Installation and Operation Guide
Bosch Security Systems, Inc.
1
8
6
2
9
10
3
7
5
4
TX RX
Callout
ᅳ
Description
1
ᅳ
Tamper switch connector
2
ᅳ
Bus address switch
3
ᅳ
MODE 2-pin jumper connector (for future use)
4
ᅳ
Bus address label
5
ᅳ
USB connector (Type A)
6
ᅳ
Heartbeat LED
7
ᅳ
RX LED (indicates packets received from the wireless network)
8
ᅳ
TX LED (indicates packets transmitted over the wireless network)
9
ᅳ
Terminal strip (to control panel)
10
ᅳ
Interconnect wiring connectors (to control panel or other compatible modules)
3.2
Cellular interface compatibility
The module supports multiple bus types. Refer to the table to determine the supported
applications and features by bus type.
Installed Bus
Function
Option/SDI
SDI2
Details
IP Event Reporting
Y
Y
TCP communication
is only supported on
SDI2
Remote Program
(RPS or A-link)
Y
Y
Requires Bosch
Cellular service or
other cellular network
access