46
en | Technical specification
Conettix Plug-in Communicator Interfaces
2017.10 | 09 | F.01U.300.740
Installation and Operation Guide
Bosch Security Systems, Inc.
7
Technical specification
Environmental
Relative humidity
Up to 93% at +32°C (+90°F) non-condensing
Operating temperature
0°C to +50°C (+32°F to +122°F)
Mechanical
Dimensions
79 mm x 128 mm x 38 mm (3.11 in x 5.03 in x 1.50 in)
Electrical
Current (operating)
Standby:
With cellular communicator = 60 mA
Alarm:
With cellular communicator = 180 mA
Voltage (operating)
(Bus operation): 12 VDC nominal
Wiring
Data bus wire gauge
12 AWG to 22 AWG (2.0 mm to .06 mm)
USB cable
USB cable (Type A to A male-to-male) – not supplied
Data bus wire length
Maximum Distance – wire size
22 AWG (0.6 mm) - 12 m (40 ft)
18 AWG (1.0 mm) - 30 m (100 ft)
16 AWG (1.3 mm) - 48 m (158 ft)
12 AWG (2.0 mm) - 122 m (400 ft)
You can extend the wire distances 300 m (1000 ft). Use a
separate power supply, such as the B520 Auxiliary Power
Supply Module
.
Compatibilities
Control panels - B450
B9512G/B8512G
B6512/B5512/B4512/B3512 (B5512E/B4512E/B3512E with
firmware v2.03 and higher)
D9412GV4/D7412GV4/D7212GV4 (v1.00.0xx+)
D9412GV3/D7412GV3/D7212GV3
D9412GV2/D7412GV2/D7212GV2 (v7.06+)
FPD-7024 (v1.03+)
CMS 6/8
CMS 40
Easy Series (v3+)
AMAX 2100/3000/4000
Solution 2000/3000*
Cellular communicators
B440/B440-C (2G/3G CDMA)
B441/B441-C (2G CDMA)
B442 (3G GPRS GSM)
B443 (3G/4G HSPA+ GSM)
B444 (4G VZW LTE)