Conettix Plug-in Communicator Interfaces
Configuration | en
21
Bosch Security Systems, Inc.
Installation and Operation Guide
2017.10 | 09 | F.01U.300.740
Selections
: 0 (disabled) - 3600 (seconds)
Keep this parameter at the default setting unless instructed by a Bosch Security Systems, Inc.
representative.
When the cellular plug-in module senses only one tower for the seconds set at this parameter,
the control panel records a Single Tower event.
When the cellular communicator senses two or more towers for the seconds set at this
parameter, the control panel records a Single Tower restoral event.
TCP Keepalive Time (sec)
Default
: 0
Selections
: 0 (disabled) to 1000 (minutes)
Time in minutes between keep-alive messages. Keep alive messages make sure that a
connection stays active.
Only change from default for high security UL1610 commercial listed installations.
5.2
Plug and Play (PnP) configuration
With PnP, the module automatically imports the control panel settings for the module and
applies them to the module.
You can use this feature for the following control panels:
–
AMAX 3000/4000 firmware version v1.5 or higher
–
B9512G/B9512G-E
–
B8512G/B8512G-E
–
B6512
–
B5512/B5512E
–
B4512/B4512E
–
B3512/B3512E
–
D9412GV4/D7412GV4/D7212GV4
–
Solution 2000/3000 firmware version v2.0 or higher
To disable this feature for PnP control panels, disable the Panel Programming Enable
parameter before you connect the module.
Notice!
By default, when you connect a field replacement module to an existing SDI2 or option bus
control panel, the control panel overrides the module settings (PnP). To keep the current
settings for the new module, use USB configuration to disable Panel Programming Enable.
Using PnP
1.
Program the control panel configuration for the module. Use RPS, or A-Link, or a keypad.
2.
Send the programming to the control panel.
3.
Set the address switch for the control panel (SDI2 control panels use address 1 or 2,
option bus control panels use address 134 or 250).
4.
Connect the module to the control panel bus.
5.
Apply power to the control panel.
The module imports the settings and then programs the connected module.
5.2.1
RPS configuration
For control panels that support RPS configuration, you can program the control panel to
configure the module with PnP.
For configuration parameters, refer to
Configuration parameters, page 17
.
You can also refer to the
RPS Help
.