Conettix Plug-in Communicator Interfaces
Configuration | en
37
Bosch Security Systems, Inc.
Installation and Operation Guide
2017.10 | 09 | F.01U.300.740
When the Transmit (TX) and Receive (RX) LEDs flash in unison at a 1-second interval, the
module successfully received the SMS. If the module received an invalid SMS, the Transmit
(TX) and Receive (RX) LEDs alternately flash at 1/2 second interval. Both flashing patterns
continue until you move the bus address switch from position "0.”
Notice!
If the LEDs indicate an invalid SMS, change the bus address switch from 0 and then back to 0
before you send a different SMS.
Refer to the tables in
Maintenance and troubleshooting, page 38
section for more information
on LEDs. Make sure that the SMS contains the correct information, and that you entered the
correct phone number for the module.
5.4.3
Exiting from CONFIG mode
1.
Change the bus address switch to the desired value, depending on the supported control
panel.
2.
Check the signal strength and Heartbeat LED for status.
5.4.4
Configuration