24
en | Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts
AUTODOME inteox 7000i - 2MP (pendant)
2020-07 | 1.0 |
Installation Manual (pendant)
Bosch Security Systems
1
1
2
3
4
5
6
2
3
4
N.
O
.
CO
M
N.
C
.
A1
GND
A2
1
PIN
PIN
P102
P103
P104
WHITE
ORANGE
BROWN
GREEN
WHITE
ORANGE
BROWN
GREEN
YELLOW
BLUE
2
3
4
5
6
7
Figure 9.1:
Alarm and relay connectors
1
4-pin Alarm
Connector (P102)
2
6-pin Alarm In
Connector (P103)
3
7-pin Relay Connector (P104)
Pin Description
Pin
Description
Pin
Description
1
Alarm Out 1
1
Alarm in 3
1
Alarm Out 4 Normally Open
2
Alarm Out 2
2
Alarm in 4
2
Alarm Out 4 COM
3
Alarm Out 3
3
Alarm in 5
3
Alarm Out 4 Normally Closed
4
Alarm Ground
4
Alarm in 6
4
Earth Ground
5
Alarm in 7
5
Analog Alarm 1
6
Alarm Ground
6
Analog Alarm 2
7
Ground
For in-ceiling mount only: Low Voltage TTL (3.3V) can also be used.
4
If you are connecting supervised alarms and relays, attach the supplied 7-pin Relay
Connector to the appropriate incoming wires. Refer to