AUTODOME inteox 7000i - 2MP (pendant)
Pre-installation Checklist | en
15
Bosch Security Systems
Installation Manual (pendant)
2020-07 | 1.0 |
4
Pre-installation Checklist
1.
Determine the location and distance for the power supply box based on its voltage and
current consumption.
You may choose to route the main power supply through an intermediate power supply
box (VG4-PSU1 or VG4-PSU2) before connecting the power to the pendant arm power
supply box (VG4-PA0).
!
Caution!
Select a rigid mounting location to prevent excessive vibration to the camera.
2.
Use only UL-listed liquid tight strain reliefs for conduits to the Power Supply Box to
ensure that water cannot enter the box. You must use water tight conduits and fittings to
meet NEMA 4 standards.
3.
Purchase the appropriate mounting hardware to use, depending on the location of the
camera, either wall mount, corner mount, or mast (pole) mount.
If your application contains a Power Supply Box, refer to
Mast (Pole), and Corner Mounts), page 21.
If you are using the Mounting Plate with a 24 V AUTODOME camera, refer to
!
Warning!
For units intended to be installed outdoors: All wiring (power and I/O cabling) connecting to
the unit must be routed separately inside different permanently earthed metal conduits (not
supplied).
!
Warning!
To minimize the potential for corrosion on the housing, use only Bosch hardware and mounts.
See number 5 (Installation in a corrosive environment) in the section
Recommended Use of
Your Camera for more information.
4.
Install all external wiring including power, control, video coax, alarms I/O, relay I/O, and
fiber optic cabling. Refer to the
Connection, page 52 chapter for required cable types
and allowed lengths.
!
Warning!
Install external interconnecting cables in accordance to NEC, ANSI/NFPA70 (for US
application) and Canadian Electrical Code, Part I, CSA C22.1 (for CAN application) and in
accordance to local country codes for all other countries.
Branch circuit protection incorporating a 20 A, 2-pole Listed Circuit Breaker or Branch Rated
Fuses are required as part of the building installation. A readily accessible 2-pole disconnect
device with a contact separation of at least 3 mm must be incorporated.
24 VAC Class 2 power supply only.
5.
If you plan to use the Intelligent Tracking feature, refer to