3
Description of the machine
Page 6 / 8
EPA assembly line for DaeP
Assembly Station
VPP 21
Station x
Station 2
Station 3
Station 4
Station 5
Station 6
Station 7
Station 8
Station 9
Station 10
Station 11
Station 12
Station 13
Station 14
Station 15
Station 16
Station 17
Station 18
Station 19
Station 20
Station 21
Station 22
Station 23
Station 24
Station 25
Station 26
Station 27
Station 28
Station 29
Station 30
Station 31
Station 32
Station 33
Station 34
Station 35
Station 36
Station 37
Station 38
Station 39
Station 40
Station 50
Station 60
Station 70
Station 80
Station 90
Station 100
Station 110
Station 120
Station 130
Station 140
Station 150
Station 160
Station 170
Station 180
Station 190
Station 200
Station 210
Station 220
Station 230
Station 240
Station 250
Station 260
Station 270
M.3000314.190_0843.195.960 /
V0.0_0613_EN_PA--ATMO2
Robert Bosch GmbH
Description of function
Dae flow Test
Pick ECU from leak test fixture and
insert in DAE mounting fixture (1).
.
Data of the ECU ( Trace Label ) are
being read by the installation via a
scanner (2) and being checked as to
the right type and as to production
progress:
.
If it is the right type, processing is
being started as the ECU is being
lowered. In this position the ECU is
being fixed and adapted via the
sealing head.
.
Now test operation is being started.
'
If it is a wrong type, processing is
not being started and the information
”ECU not for the station” appears on
the VCP20.
1
2
Sequence for OK parts
Is the test finished, the fixture is
Un--clamped and the lifting unit lifts the
ECU again. The result is being reported
to the operator via the signal lamps.
In case the test was ”iO” (1), the ECU may
be withdrawn and put to the next station for
further processing.
'
In case the test was ”not iO”, the test
result must be acknowledged with
the illuminated button. Then the
ECU must be put into the niO
oddments box. Work piece carrier
may be pushed out of the station.
1