Plumbing and Mechanical
LEAK TEST PROCESS
High-Side inlet and Low-Side inlet valves are opened to equalize high and low sides of system being serviced. Unit
checks low-side transducer for rise in vacuum (this is not a service menu test.).
Figure 4-12. Leak Test
Heat Exchanger/
System Oil
Separator
Filter/Dryer
Compressor
(COMP)
Compressor
Oil Separator
Oil Return
Solenoid
(S7)
Oil Drain
Solenoid
(S6)
Accumulator
Transducer
FRONT PANEL
MANIFOLD
HOSE FLUSH
MANIFOLD
BULKHEAD
INJECTION
MANIFOLD
Charge
Solenoid
(S3)
Charge Check
Valve
Low Side
Ball Valve
High Side
Ball Valve
Recover
Check
Valve
Recover
Solenoid
(S1)
Low Side
Transducer
Oil Drain
Bottle
High Side
Gauge
Low Side
Gauge
Vacuum
Solenoid
(S2)
High Pressure
Switch
Vacuum Pump
(PUMP)
High Side
Service Hose
Low Side
Service Hose
HS
Bulkhead
LS
Bulkhead
Hose Flush
Check
Valve
Pressure Relief
Air Purge
Pressure Relief
Internal
Storage
Vessel
Vapor
Check
Valve
Tank Liquid
Solenoid
(S4)
Oil Inject
Bottle
Oil Inject
Solenoid (S5)
Oil Inject
Check Valve
Service
Port
Liquid
Ball
Valve
Suction
Discharge
Intermittent
Energized
Tank
Pressure
LEAK TEST