ACS 561 Service Manual
Robert Bosch GmbH
SP00D00517
2018-07-11
20
Diagnostics and Testing
SERVICE CENTER MENU OPTIONS
Service Menu
Consult the Technical Service Bulletins
for the latest software version as
applicable. To navigate through the
Service Menu, use Keypad and arrow
keys shown below.
These are the Service Options at the time of printing this service manual. Some
options may be added or deleted in future circuit board and software updates and
revisions.
Never change the default settings unless directed from the factory. Otherwise the
unit may fail to operate properly.
Never give the programming or service codes to customers.
Diagnostics and Troubleshooting
1. Turn unit on and allow it to run through the
boot sequence.
2. From the Setup Menu, press Service Menu.
3. Enter 4-3-5-0-6 at the password prompt,
then press Select (F1). The following
displays.
Calibrate Load Cells
The ISV scale is the only load cell in the
ACS 561. After selecting Calibrate Load Cells,
the following displays:
1. Select Calibrate Load Cells from the Ser-
vice Menu by pressing F1. The following
displays:
Perform the following:
4. To exit the Service Menu, press Exit (F2).
5. To perform any of the checks in the Service
Menu, scroll to the desired test listed below
and press, Select (F1).
• Calibrate Load Cells
• Service Leak Check
• Calibrate Air Flow
• End User Install
• Set Tank Tare
• Maintenance Counters
• Service Clear
• Output Test
• Service Vacuum
• Input Test
• Keypad Test
• Set Boot Mode
• Set SN
(Serial Number)
• Select Model
• Set Mfg Date
(Manufacturing Date)
• Reset Board
• Configuration
• Reset All