Assembly 33/68
3 842 560 593/2020-07 ActiveShuttle: ActiveShuttle 1.0,
Bosch Rexroth AG
7.5.1
Connecting the charging station electrically
WARNING
High electrical voltage!
Risk of severe injury or death from electric shock.
Disconnect the relevant system component before performing any maintenance
or repair work.
Secure the system against being unintentionally switched on again.
Only operate the charging station with a circuit breaker ≤ 16 A with triggering
characteristic B or C.
Risk of injury by bridging the charging contacts of the charging station!
By bridging the charging contacts, there is a risk of damage, sparks, overheating
and fi re.
Do not place any objects, especially electrically conductive or fl ammable
objects, in the area in front of the charging contacts of the charging station.
CAUTION
Risk of injury due to improper installation of the charging station!
Route the connection cable according to the country-specifi c specifi cations for
avoiding risks.
• Electrical work may only be carried out by qualifi ed personnel!
• Comply with the standard DIN EN 60204 (previously: VDE regulation VDE 0100) for
Germany, or the corresponding regulations in the country of use.
The charging station has a GST plug-in system.
Further details on the connection can be found in the enclosed document
"General safety instructions for electrotechnical installation of MPS components"
3 842 358 820.