Insert the control box with the affixed compensation
plates from the inside of the panel through the
prepared holes in the panel. On the front, position the
power-setting collar and tighten it using the
accompanying nut and support bracket at a maximum
torque of 10 Nm.
In order to maintain a horizontal position, the control
box has to be affixed to the inside of the front panel
with four screws (e.g. chipboard screws DIN 7997).
Now affix the power-setting collar to the front panel
from the front using two screws.
Finally, you can attach the operating knob. When doing
so, the distance of 18.5 mm must be maintained.
The fine adjustment of the knob distance can be
carried out using the internal adjusting screw and a
hexagon wrench key. Compare the connection data
(voltage and frequency) on the type
plate with that on the mains connection before
connecting the control box.
These data must coincide to prevent damage to the
appliance. If in doubt, ask your electrician.
Ensure that the plug remains easily accessible after
the appliance is installed. Plug the cable for the
extractor fan into the designated socket.
Compensationp
lates
Installation of the control box
D
Power-setting collar
Содержание PL 540
Страница 11: ...11 Fl chenb ndige Montage Aufsatzmontage Ausschnittsma e Kombinationsm glichkeiten D...
Страница 22: ...22 Flushmounting Above surfaceinstallation Dimensions combination options D...
Страница 33: ...33 Montage adjacent Montage en saillie Dimensions de la d coupe Combinaisons possibles de commande F...
Страница 44: ...44 Vlakinbouw Opbouwmontage Uitsparingsmaten combinatiemogelijkheden NL...
Страница 66: ...66 Montajea ras de superficie Montajesuperpuest Medidas de recorte posibilidades de combinaci n E...