8.5
Size 2 ACT4XX (1.85…4.0 kW, 400 V)
Type
ACT4XX
-12
-13
-15
-18
Size
2
Output, motor side
Recommended motor shaft power
P
kW 1.85
2.2
3.0
4.0
Output current
I
A
4.2
5.8
7.8
9.0
3)
I Longt overload (60 s)
I
A
6.3
8.7
11.7
13.5
I Shortt overload (1 s)
I
A
8.4
11.6
15.6
18.0
Output, braking resistor
Min. braking resistance
R
Ω
136
136
136
92
Recommended braking resistor (U
dBC
= 770 V)
R
Ω
300
220
148
106
Input, mains side
Mains current
2)
I
A
4.2
5.8
6.8
1)
7.8
1)
Fuses
I
A
6
10
Type UL 600 VAC RK5
I
A
6
10
Mechanical
Dimensions
HxWxD mm
250 x 60 x 175
Weight approx.
m
kg
1.6
Connection terminals
A mm
2
0.2 … 1.5
Ambient conditions
Energy dissipation (2 kHz switching
frequency)
P
W
68
87
115
130
Output current
(Maximum current in continuous operation)
Frequency inverter
nominal power
Switching frequency
2 kHz
4 kHz
8 kHz
16 kHz
1.85 kW
4.2 A
4.2 A
4.2 A
2.9 A
2.2 kW
5.8 A
5.8 A
5.8 A
3.9 A
3.0 kW
7.8 A
1)
7.8 A
1)
7.8 A
1)
5.3 A
4.0 kW
9.0 A
1)
9.0 A
1) 3)
9.0 A
1) 3)
6.1 A
3)
1)
Connection requires a commutating choke.
2)
Mains current with relative mains impedance ≥ 1% (see chapter „Electrical
installation“)
3)
Reduction of switching frequency in thermal limit range
Содержание ACTIVE ACT2 Series
Страница 1: ...Quick Start Guide 132 kW...
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 13: ...12 20 Quick Start Guide ACT 11 I Grandezza 5 c c1 a a1 a2 x b b1 x x 100 mm...
Страница 15: ...12 20 Quick Start Guide ACT 13 I Grandezza 6 a a1 a2 x x 100 mm b b1 x c c1...
Страница 62: ...60 Quick Start Guide ACT 12 20 GB Size 5 c c1 a a1 a2 x b b1 x x 100 mm...
Страница 64: ...62 Quick Start Guide ACT 12 20 GB Size 6 a a1 a2 x x 100 mm b b1 x c c1...
Страница 112: ...110 Quick Start Guide ACT 12 20 D Baugr e 5 c c1 a a1 a2 x b b1 x x 100 mm...
Страница 114: ...112 Quick Start Guide ACT 12 20 D Baugr e 6 a a1 a2 x x 100 mm b b1 x c c1...
Страница 161: ...12 20 Quick Start Guide ACT 159 F Taille constructive 5 c c1 a a1 a2 x b b1 x x 100 mm...
Страница 163: ...12 20 Quick Start Guide ACT 161 F Taille constructive 6 a a1 a2 x x 100 mm b b1 x c c1...
Страница 212: ...210 Quick Start Guide ACT 12 20 E Tama o 5 c c1 a a1 a2 x b b1 x x 100 mm...
Страница 214: ...212 Quick Start Guide ACT 12 20 E Tama o 6 a a1 a2 x x 100 mm b b1 x c c1...
Страница 255: ......
Страница 256: ......
Страница 257: ......
Страница 258: ...COD VEC 370 R4...