11.2.1
Statemachine diagram
State machine:
Control word:
The device control commands are triggered by the following bit patterns in the status
word.
Control word
Command
Bit 7
Bit 3
Bit 2
Bit 1
Bit 0
Transitions
Fault reset Enable
operation
Quick
stop
(Low
active
Enable
voltage
Switch on
Shutdown
X
X
1
1
0
2, 6, 8
Switch on
X
0
1
1
1
3
Enable operation
X
1
1
1
1
4
Disable voltage
X
X
X
0
X
7, 9, 10, 12
Quick stop
(Low active)
X
X
0
1
X
7, 10, 11
Disable operation
X
0
1
1
1
Fault reset
0
1
x
x
x
x
15
“X” means any value.
Transition 3 (command “Switch On” [0x07]) will only be processed if Bit 4 “Voltage ena-
bled” of the Status word is set.