11.1.1
Device state machine
State machine:
4 switched on
0x23
5
operation
enabled
0x37
1
not ready to
switch on
0x00
8
fault
0x08
quitt fault
start drive
stop drive
Status word
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Switched on
1
0
0
0
1
1
Operation enabled
1
1
0
1
1
1
Fault
x
x
1
x
x
x
“x” means any value.
Bit 7 “Warning” can display a device-internal warning message at any time. The current
warning is evaluated by reading the warning status with parameter
Warnings
270.
Bit 10 “Target reached” is set when the specified reference value is reached. In the
special case of power failure regulation, the bit is also set when the power failure regula-
tion reaches the frequency 0 Hz (see frequency inverter Operating Instructions).
For "Target reached“, there is a hysteresis (tolerance range) which can be set via the
parameter
Max. control deviation
549 see frequency inverter operating instructions).
Bit 11 “Internal limit value active” indicates that an internal limit is active. This may
be the current limit, the torque limit or the overvoltage control. All functions will result in
the reference value being left or not reached.
Bit 15 “Warning 2” signals a critical operating state which will result in a fault switch-off
of the frequency inverter within a short time. This bit is set if there is a delayed warning
relating to the motor temperature, heat sink/inside temperature, Ixt monitoring or mains
phase failure.
52
Agile
VABus/TCP
12/13