The new settings will be saved in a buffer memory, but not transmitted to the module.
On the network side, they will not be active.
In the case of incorrect entries, the values can be overwritten. Old values can be re-
stored via parameter 1437
IP-Command
= “1 – Reload IP-Settings”.
The “R/W” activates the “Update all parameters in current window regularly” function:
NOTE
Before applying the new IP settings to the module, make sure that the “R/W” button is
activated.
•
Apply the new IP settings to the module via parameter 1437
IP-Command
= “0 – Apply”.
The module will reject non-permissible IP settings and will restore the last permissible
settings automatically. After execution of the “Apply” command, all IP settings will be
reset and the new settings will be overwritten by the old settings.
7.4.2.2
When an error occurs in the frequency inverter, an e-mail message can be sent automatically to re-
port the incident to the Service department, for example. To activate the e-mail function and define
the e-mail text, two parameters are used:
Parameters
No.
Description
1440
Email Function
1441
Email Text (Body)
The contents of the e-mail message is pre-defined. The reference heading is given and cannot be
edited.
Reference:
Frequency inverter type, frequency inverter name (from parameter 29
User
name
), IP address, error number
E-mail text:
Optional text (max. 40 characters), defined in parameter 1441
Email Text
(Body)
.
Example:
Reference: AGL Main Drive machine no. 5, 172.22.5.145, F0400
Please contact Mr. Doe, extension 2121.