52
Operating Instructions AEC
11/17
AEC 401
Mains cable
PE-conductor
-43
103.9 kVA
70 mm²
1x35 mm²
-45
124.7 kVA
95 mm²
1x50 mm²
-47
145.5 kVA
2x70 mm²
1x70 mm²
-49
173.2 kVA
2x95 mm²
1x95 mm²
-51
160 kVA
150 mm²
95 mm²
-53
200 kVA
240 mm²
120 mm²
-55
250 kVA
2x120 mm²
120 mm²
-57
315 kVA
2x150 mm²
150 mm²
-59
355 kVA
2x185 mm²
185 mm²
-61
400 kVA
2x240 mm²
240 mm²
Relay output
Control terminals
1
2
3
0.2 … 1.5 mm
AWG 24 … 16
2
Phoenix ZEC 1,5/3ST5,0
0.2 … 1.5 mm
AWG 24 … 16
2
0.25 … 1.5 mm
AWG 22 … 16
2
0.25 … 1.5 mm
AWG 22 … 16
2
S3OUT
X10
X10
0.14 … 1.5 mm
AWG 30 … 16
2
Wieland DST85 / RM3,5
0.14 … 1.5 mm
AWG 30 … 16
2
0.25 … 1.0 mm
AWG 22 … 18
2
0.25 … 0.75 mm
AWG 22 … 20
2
0.2 … 0.3 Nm
1.8 … 2.7 lb-in