Version 1.05 / June 2008
BOMAR, spol. s r.o.
Extend 900.720
Těžební 1236/1
62700 Brno
CZECH REPUBLIC
22
1
Display
There are described all processes on display.
2
Safety circuit switching on
Switch on the safety circuit by pressing button.
3
Cooling system selection
You can select from three possibilities:
Cooling with Microniser
0
Without cooling
Cooling with water
4
START - Switch on the semi-automatic cycle
By pressing
6
and button
4
is starting only the band saw drive. It is stopped with button
5
.
5
STOP - Switch off the engine of the band saw
It stops the engine of the machine. With holding button STOP during the time 2 second
is stopped hydraulic engine ( if it running). The hydraulic engine is started automatic on
switch whatever motion.(Open vice, close,
Lift the saw arm, lower) or the cycle is
starting with button Start.
6
Close the vice
When this button is pressed, the vice is opened.
This button may be used in semi-automatic cycle.
7
Open vice
Vice is opened after pressing this button.
8
Lift the saw arm
9
Lower the saw arm
If this button is pressed with
8
button together, the saw arm is starting chute on the
cutting material with accelerated shift. ATTENTION! If you will be running with
accelerated shift until the cut, the saw band may be damaged.
10
TOTAL
– STOP button
In emergency causes the machine must be immediately switched off.
11
LED
- control lamp blink by cycle.
12
Frequency convertor
Turn to change the speed of the saw band.
13
Cutting pressure manometer