Bolin Technology Visca VCC-BL-VNS-07202020 Скачать руководство пользователя страница 15

15 

 

Part Two 

Bolin IP web interface    

User Quick Notice Guide 

This Visca-Over-IP Serial Control Converter does not have video IP streaming functionality.  

All features related to IP video streaming are not functional. 

IP feature is limited with the web GUI. 

This Quick Guide is for Bolin FHD/4K Dual Output PTZ camera IP web interface use. Please read it carefully before you start 
using your camera and follow the instruction to effectively use the camera/IP device, or check it when you are having some trouble 
with IP video streaming and IP control. 

Please contact Bolin technical support team at 

www.bolintechnology.com

 if you have more questions or having trouble that is not 

included in this guidance. 

This paper is part of product user guide, please refer to our product user manual if you have questions regarding how to use the 
camera. User manual can be downloaded at Bolin website. 

  

Note:  

 

Currently the IP camera only supports Internet Explorer 11 browser, other browsers compatibility will be available 
via future firmware upgrading.  

 

It will be required to download the Controls (VideoPlugin) for the first time login, please click the download link 
and follow the prompts to download and install it.

 

 

After the VideoPlugin has been installed, you may be prompted to update the VideoPlugin, please uninstall the 
old version of Plugin before you download and install the new version of Plugin.

 

 

Login  

The default static IP address of the camera is 
192.168.0.13, and default subnet mask is 
255.255.255.0. Please change your PC/laptop’s IP 
address to located within the same subnet as the 
camera. 

The login procedure as following: 

 

Open the Internet Explorer 11 browser, running 
it as Administrator 

 

Browser to the login page by entering 

http://192.168.0.13:8080

 (must entering the port 

8080) 

 

The default user name is admin, password is 
admin 

 

NOTE: If the camera IP address has been modified, the login page URL should b

http://x.x.x.x:8080

 (x.x.x.x is the correct IP 

address of the camera) 

IP Firmware Update 

You have to add the camera IP interface URL to the 

IE11 browser’s Trusted Sites before to start firmware update, otherwise, you 

will be prompted that the firmware file cannot be opened.

 

 

 

Click Setting button of IE11 browser, access to Internet Option > Security page. 

 

There has Trusted Sites option, click and add the URL to the list. 

 

Please don’t check the “Require server verification (https:) for all sites in this zone” option box. 

 

Go back to maintenance page and now you can start the firmware update. 

NOTE:

 The firmware update including two steps: 

 

The First step is to select the firmware file and upload it to the camera IP module, there will be a percentage progress bar 
display to indicate the upload status on the page. 

 

The Second step is the firmware burning and updating, there is no progress bar prompt in this step, the burning and 

Содержание Visca VCC-BL-VNS-07202020

Страница 1: ...1 Visca Over IP To Serial Control Converter USER MANUAL VERSION VCC BL VNS 07202020 2020 Bolin Technology ...

Страница 2: ...ONTROLLING SONY SERIAL CONTROL PTZ CAMERA 13 FIRMWARE UPGRADE 14 UPGRADING MCU FIRMWARE 14 UPGRADE VIA IP 14 USER QUICK NOTICE GUIDE 15 NETWORK CONNECTION 16 LOGIN PREPARATION 16 CHECK BEFORE LOGIN 16 LOGGING IN TO THE WEB INTERFACE 17 NOTE FORGOT PASSWORD 17 IP FINDER TOOL 17 NETWORK NETWORK SETTING NETWORK 18 NETWORK NETWORK SETTING PORT 18 NETWORK NETWORK SETTING VISCA OVER IP 18 SYSTEM SYSTEM ...

Страница 3: ...ment are subject to change without prior notice Updates will be added to the new version of this manual We will readily improve or update the products or procedures described in the manual Best effort has been made to verify the integrity and correctness of the contents in this document but no statement information or recommendation in this manual shall constitute formal guarantee of any kind expr...

Страница 4: ...ntil it is removed Do not use organic solvents such as benzene or ethanol when cleaning the surface Regulatory Compliance FCC Part 15 This equipment has been tested and found to comply with the limits for digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environm...

Страница 5: ...5 WHAT S IN THE BOX Accessories Optional ...

Страница 6: ...wing models BL VNS 1 Features Hardware Visca over IP solution Support 802 3at PoE Provide Serial RS 232 RS 422 485 control over Ethernet by Visca over IP protocol MCU firmware upgradable via USB port IP firmware upgradable via IP web interface Power DC 12V Power input ...

Страница 7: ... for IP network connection support PoE power supply IEEE 802 3at 4 Heat sink surface panel All aluminum body for quick heat dissipation 5 RS 422 Control Port Use RJ45 to RS 422 extension adapter cable or make CAT6 cable to remotely control PTZ camera 6 RS232 Control Port Use RJ45 to RS 232 extension adapter cable or make CAT6 cable to remotely control PTZ camera 7 USB 2 0 Port Used for MCU firmwar...

Страница 8: ...8 System Configuration Port Diagram ...

Страница 9: ...rce has sufficient power budget to power the camera or some features may not function properly VISCA over IP Control With VISCA over IP function you can control the camera using VISCA protocol on a controller equipped with IP communication capabilities via LAN This converter converts control signal via Visca Over IP to Serial control signal to control PTZ camera with only serial control functional...

Страница 10: ...roller to the network Configure the controller to access the camera s IP address and VISCA over IP port The IP port within on your control must be set to 52381 to communicate with the camera Select VISCA protocol on your IP control device Recommended way to re assign the IP address 1 Create a local network within which the camera and your PC Laptop are connected 2 Install and run the IP FINDER too...

Страница 11: ...ntrol with the controller and the camera successfully please refer to your controller and camera user guides 1 Use extension cables included RJ45 to RS422 232 Phoenix terminal contact adaptor to make RS232 connection for your camera 2 You can use CAT5 6 T 568B Standard Ethernet cable direct connect between the camera and the converter to make RS232 connection by following the pin definition below ...

Страница 12: ...andard shown as below 3 Use extension cables RJ45 to RS232 8 pin Mini Din adaptor Sold separately to make RS232 connection for your camera RS422 serial control via Visca Over IP NOTE This Visca Over IP converter does not support Daisy Chain multiple camera control This diagram shows how to make the connection correctly for you to make the control with the controller and the camera successfully ple...

Страница 13: ... SONY serial PTZ camera Please consult your seller to gain the correct version of the firmware This Visca Over IP converter does not support Daisy Chain multiple camera control This diagram shows how to make the connection correctly for you to make the control with the controller and the camera successfully please refer to your controller and camera user guides 1 Use extension cables RJ45 to RS422...

Страница 14: ... LED indicator to show the upgrade progresses The verify is the new firmware is upgraded correctly or not go to the converter web GUI System Maintenance to check the firmware version NOTE The firmware upgrade process is intended to be performed under the supervision of a BOLIN Authorized repair technician For assistance with this please contact your authorized BOLIN Technology dealer installer or ...

Страница 15: ... old version of Plugin before you download and install the new version of Plugin Login The default static IP address of the camera is 192 168 0 13 and default subnet mask is 255 255 255 0 Please change your PC laptop s IP address to located within the same subnet as the camera The login procedure as following Open the Internet Explorer 11 browser running it as Administrator Browser to the login pa...

Страница 16: ...era and the switch or router Login Preparation After you have completed the installation in accordance with the quick guide connect the camera to power to boot it After the camera is booted you can access the camera from a PC client using Internet Explorer or a Video Management System VMS The following uses Internet Explorer 11 on a Microsoft Windows 10 operating system as an example Check before ...

Страница 17: ...th Remember Password selected you do not need to enter the password each time when you login to ensure security you are not advised to select Remember Password NOTE Forgot Password A message will pop up which reads Please contact the manufacturer for disposal You can download the IPCSearch tool from the www bolintechnology com Unzip the file and configure your laptop in the same subnet as camera s...

Страница 18: ...54 o RTSP is the protocol used to pull real time video over the network using VLC Player or other network video compatible software o Changing this port number will change the way the RTSP video can be viewed Most RTSP streaming software uses port 554 by default therefore it is not recommended that this port number be changed o URL for receive RTSP streaming is rtsp IP 554 PSIA Streaming channels ...

Страница 19: ...ble technical support cases System System Setting Time This interface allows user to configure the date time settings of the camera System Time o You can check the Sync with Computer Time option and synchronize the camera operation time with your PC time system Date Format o Two formats selectable o Y M D or D M Y Time Format o Two formats selectable o 24H or 12H standard Time Zone o WEST 12 to EA...

Страница 20: ...tes before to start upgrade otherwise you will be prompted that the file cannot be opened o Click Setting button of IE browser access to Internet Option Security page o There has Trusted sites option click and add the URL to the list o Please don t check the Require server verification https for all sites in this zone option box o Go back to maintenance page and now you can start the upgrade Devic...

Страница 21: ...21 www bolintechnology com 2082 TECHNOLOGY LLC dba BOLIN TECHNOLOGY ...

Отзывы: