14.Never operate the compressor when one or more parts (e.g cable, plug)
are damaged, it is not in perfect working order, or damage is detected or
suspected.
15.Observe all safety and danger signs on the compressor.
Integrated DRL 6-2 compressed air dryer (EO 6 D, EO 11 D) and attached
DS compressed air dryer (EO 6 DR, EO 17 D, EO 22 D)
The integrated Type DRL refrigerant compressed air dryer is also referred to
below as a DL dryer.
16.For all information and tips on the attached DS dryer, please read the sep-
arate operating instructions for the dryer.
17.BOGE accepts no liability for non-observance of the safety regulations dur-
ing handling, operation, maintenance or repair work.
18.The operational capability and service life of the refrigerant compressed air
dryer as well as the avoidance of premature repairs are dependent on the
correct operation, maintenance and professional repair of the device ac-
cording to the instructions given in these operating instructions.
Electrical equipment
of the compressor
DANGER
Risk of electric shock!
Coming into contact with live parts inside the switch cabinet or where the
electrical equipment is housed can be fatal.
Î
Never open the electrical equipment and switch cabinet during operation.
Î
Work on the electrical equipment may only be carried out by an author-
ised and qualified electrician.
Î
Prior to all work:
1. Disconnect all power infeeds using a mains disconnecting device.
2. Take precautions to prevent them being switched back on again.
3. Check that all system components are de-energised.
4. Earth and short circuit.
5. Cover or enclose adjoining live parts.
Î
Check the electrical equipment of the compressor at regular intervals for
defects such as loose connections or scorched cables. Have any defects
rectified immediately.
Î
Make sure to have all electrical systems and fixed electrical installations
checked by a qualified electrician at least every four years. Any modifi-
cations carried out after inspection must conform to EN 60204-1.
Î
Check that all safety devices on the machine are functioning properly at
regular intervals.
Î
Only use original fuses.
Î
Never touch the relay outputs and the I/O terminals. Dangerous voltage
may still be present even when the machine is disconnected from the
mains.