BOGE Operating instructions for scroll compressors, series EO 6...EO 22 D
Page 5
General
1.6
System subject to monitoring
Data on the rating plate
Enter the technical data for your compressor from the rating plate or enclosed
data sheet into the figure below. If you have any queries this ensures that you
always have the most important information to hand.
Fig. 1.1: Data on the rating plate
1.6 System subject to monitoring
A compressor is often part of a pressure vessel system, which is subject to
monitoring according to § 14 of the BetrSichV (Ordinance on Industrial Safety
and Health). A system subject to monitoring shall only be put into service for
the first time or after significant modifications if an approved body or a compe-
tent person has inspected the system to ensure it is in proper working order
with regards to its assembly, installation, the conditions of erection and safety,
taking into consideration its intended mode of operation.
According to the BetrSichV, the compressed air system shall be subjected to
recurrent inspections by an approved body or competent person.
The operator must determine the inspection intervals within six months of
commissioning and come to an agreement with the approved inspection body.
The recurrent inspections must be arranged within the specified time frame
and documented by the operator.
Operators located outside the Federal Republic of Germany must observe the
national regulations for the country in which the device is used.
m³/min
bar
kW
Type
Year of manufacture
Maschine number
Volume flow
max.
Final compression pressure
Motor speed
rpm
Motor output