Appendix
8.3
Pneumatic circuit diagrams
Page 76
BOGE Operating instructions for scroll compressors, series EO 6...EO 22 D
Classification and
assessment of pressu-
rised components
Compressor / compressed air systems and compressor stations are assem-
blies according to the PED. The classification of an assembly according to the
PED is based on the highest category of the individual components.
Outcome of the assess-
ment
Every aspect of the assembly of the pressurised compressor components
mentioned above is excluded from the scope of the Pressure Equipment
Directive (PED).
Justification:
According to Art. 1, 2.f of the PED, assemblies which in their
entirety would fall into Category 1 at the highest are excluded from the scope
of the PED if they are covered by the Machinery Directive.
Installation in com-
pressed air systems
The installation of the assemblies mentioned above in a compressed air sys-
tem does not constitute a new assembly in the sense of the PED, provided
that the integrated components are excluded from the scope of the PED.
8.3 Pneumatic circuit diagrams
The following pages contain the individual pneumatic circuit diagrams for the
different machine types.
Compressor compo-
nents
Pressure volume
product Ps*V
Pressure nominal width
product Ps*DN
Classification / assess-
ment according to PED
Conformity assessment
procedure to be applied
according to directive...
Pipelines
(compressed air pipe
system, cooler, hoses)
Ps * DN < 1000
Art. 4, 3
PED
Safety equipment *
(safety valves)
n.a.
Category IV according to
Art. 2,4 (not taken into
consideration for assembly
assessment according to
Art. 14)
PED
Compressed air receiver
Ps * V > 3000
Excluded from scope
according to Art. 1, 2.c
Simple Pressure Vessels
Directive
Compressor / compressor
block
n.a.
Excluded from scope
according to Art. 1, 2.j
Machinery Directive
Optional equipment
(e.g. filter, dryer,
condensate drain,
cyclone separator)
misc.
Art. 4, 3
PED