7.1 Model Number System

7.0 Specifications

Page 25

Sonic-Pro

Page 26

Sonic-Pro

_________

General Operation__________

Measuring Principle

Ultrasonic - Transit Time.

Fluid Types

Water to 5% (0 to 50,000 ppm) particulate. 

Fluid Velocity Range

0.5 to 30 feet per second (0.15 to 9 meters per second)

Nominal Pipe Sizes

0.50, 0.75, 1.00, 1.50 and 2 inch IPS pipe sizes

Accuracy

+/-2% of rate > 1 ft/sec, +/-0.10 ft/sec < 1 ft/sec

_____Inline Pipe Fitting/ Transducer____

Pipe Fitting/Transducer

NEMA 4X (IP66), High Density Polyethylene

Connection option A - 

High Density Polyethylene, Female NPT threads

O

O

O

O

Maximum fluid temperature: 14 F to 160 F (-10 C to 71 C)
Maximum operating pressure: 300 PSI/g at 

O

70 F

Connection option B - 

316 Stainless Steel, Female NPT threads

O

O

O

O

Maximum fluid temperature: 14 F to 160 F (-10 C to 71 C)
Maximum operating pressure: 

O

300 PSI/g at 70 F

Connection option C - 

PVC, Female Slip

O

O

O

O

Maximum fluid temperature: 14 F to 140 F (-10 C to 60 C)
Maximum operating pressure: 

O

300 PSI/g at 70 F

Connection option D - 

316 Stainless Steel, 150# Flat Face Flange (without gaskets)

O

O

O

O

Maximum fluid temperature: 14 F to 160 F (-10 C to 71 C)
Maximum operating pressure: 

O

300 PSI/g at 70 F

Cable - field replaceable

Shielded coaxial RG/U Type: 59. FEP jacket, black. RoHS Compliant
Connector: thermoplastic locking. NEMA 4X (IP66)
Available lengths: 10ft (3m), 25 ft. (7m), 50 ft. (15m), 100 ft. (30m)

_______SPU (Signal Processing Unit)_______

Enclosure

NEMA 4X (IP66), Powder coated aluminum, SS clamps and hardware. 
Dimensions: 7.24H x 6.69W x 3.11D inches (184H x 170W x 79D mm)
Weight 3.7 lb. (1.7 Kg.)

Mounting

Pipe fitting, wall or pipe (vertical or horizontal) mounting. Hardware included.

Power Requirements

15-28 VDC; 15 watts maximum

Operating Temperature

O

O

O

O

O

O

O

O

14 F to 140 F (-10 C to 60 C) 

Storage:

 

-40 F to 158 F (-40 C to 70 C)

Display

VGA backlit LCD, UV resistant.
Simultaneous Rate and Total: 8 digit maximum
Decimal location configurable to 5 places.

Display Language

English

Keypad

Six-button positive action tactile switch keypad.

Security

Programmable 4-digit password.

Display Volume Units

Independently configurable Rate and Total display units in: U.S. Gallons, 
ounces, barrels (US liquid), barrels (US oil), cubic ft, acre ft, Imperial (British) 
gallons, liter, cubic meter, or user defined “custom” units. 
Rate display in feet or meters per second.

Display Time Units

Seconds, minutes, hours, days. 

Display/Output Response Time

1.0 second. 

Flow Rate Display Averaging

Selectable: 0.50, 1.0, 2.5, 5.0 (default), 10.0 seconds. 

Data Outputs

!

Isolated 4-20 mA output - fully configurable, invertible

!

0-1000 Hz Pulse output - fully configurable, invertible

Data Logging

Date/time stamped flow rate and flow total data in FAT32 file format, easily 
imported into Excel. Configurable to trigger on time interval (1-999,999 sec), 
rate and/or total set-point values. Store up to 191,800 log events in the 
memory buffer, downloadable to flash memory via USB port.

Process Control

Two independently configurable relays.
Type: FORM C
Load capacity: 30V, 100mA max (ext. supplied)

!

Configure to flow rate for high/low/range rate alarm. Programmable 

release values enable auto release or manual latching operation.

!

Configure to flow total for automatically triggered, timed batch operations 

for proportional feed applications.

External Communications

Computer connection via optional 

Communications Modules:

!

Industrial Ethernet/IP

!

Modbus RTU

!

Modbus TCP

!

Profinet RT/IO

!

Profibus DPV1

When equipped with a communications module, the following data 
transfer is possible:
1.  Flow rate
2.  Flow total
3.  Fault/warning codes
4.  Log data
5.  CC1 relay status
6.  CC2 relay status
7.  Current fluid sound speed
8.  Number of Goodness of Measurement boxes filled in
9.  Analog output value (4-20 mA)
10.  Frequency output value (0-1000 Hz)
11.  Firmware version

INLINE PIPE FITTING

TEMPERATURE VS PRESSURE

PVC Adapters

HDPE and 316SS Adapters

50

100

150

200

250

WORKING PRESSURE  (PSI/g) 

70° F (21° C)

110° F (43° C)

150° F (65° C)

TEMPERA

TURE  F (C)

300

80° F (27° C)

90° F (32° C)

100° F (38° C)

120° F (49° C)

130° F (54° C)

140° F (60° C)

160° F (71° C)

Pipe 

Size

05

Model 

Number

Min. Flow (0.5 fps)

07

10

15

20

 1/2”

 3/4”

1”

1-1/2”

2”

0.36 (1.36)

0.67 (2.54)

1.12 (4.24)

2.75 (10.4)

4.60 (17.4)

GPM (LPM)

Max. Flow (30 fps)

GPM (LPM)

21.9 (82.9)

40.4 (153)

67.3 (255)

165 (625)

276 (1045)

FLOW RANGES

Sonic-Pro S4 Part Number Matrix

 

Signal Processing Unit (SPU) - Display

Sonic-Pro Base model

S4

Communications Options

D

Modbus RTU

E

Modbus TCP/IP

F

PROFIBUS-DPV1

G

PROFINET RT/IO

X

H

Industrial Ethernet/IP

Input Power (15 - 30 VDC required - all units include D cell battery pack, 4 D cell batteries are not included)

1

U.S. 115VAC~50/60 / 15VDC plug-in transformer

2

Europe 220VAC~50/60 / 15VDC plug-in transformer

3

U.S. 230VAC~50/60 / 15VDC plug-in transformer

Inline Pipe Fitting/Transducer

C

Inline pipe fitting/transducer (see pipe size and material options below)

X

Without inline pipe fitting/transducer

Transducer Cable Length and Connection Type

A

10 ft cable length - with field replaceable liquid-tight cable plug and socket

B
C
D
X

Display mounted directly on the inline pipe fitting/transducer - no transducer cables

Standard 4-20mA and High Speed Pulse output only

Without power supply (customer supplies 15-30 VDC)

0

25 ft cable length - with field replaceable liquid-tight cable plug and socket
50 ft cable length - with field replaceable liquid-tight cable plug and socket
100 ft cable length - with field replaceable liquid-tight cable plug and socket

Z

Inline pipe fitting transducer only (no display) - without cables 

Sonic-Pro Transducer

ST

Transducer Model

ST

C

B

Sample Number

-

-

Transducer Cable Length and Connection Type

Pipe Configuration Specifications 

-

015AG

07

A

Sample Part Number

D

1

C

A

S4

Inline Pipe Fitting/Transducer

Pipe Connection Type and Material 

A

F/NPT , HDPE

Slip, PVC

Inline Body Material 

G

Polyethylene (HDPE)

Fluid Sound Speed Working Range

Water like fluids 1500 +/- 100 m/sec

0

Inline Pipe/Transducer Only

B

F/NPT, 316SS

D

Flange, 316SS

C

0

G

2”

05

07

10

15

20

1/2”

3/4”

1”

1-1/2”

Nominal IPS Pipe Connection Size

Industries, Ltd.

Industries, Ltd.

ProSeries

by Blue-White Ind.

d

Industries, Ltd.

Industries, Ltd.

ProSeries

by Blue-White Ind.

d

Содержание ProSeries SONIC-PRO S4 Series

Страница 1: ...Installation and Operating Manual 2 TWO YEAR WARRANTY ProSeries Series S4 Ultrasonic Flow Meter Industries Ltd Industries Ltd ProSeries by Blue White Ind d SONIC PRO d...

Страница 2: ...DING THE SAFE USE OF THIS PRODUCT AND OTHER TECHNICAL ASSISTANCE MAY BE DIRECTED TO Blue White Industries 714 893 8529 techsupport blue white com CAUTION risk of electric shock CAUTION risk of danger...

Страница 3: ...ions of other chemicals or other chemicals entirely may be acceptable provided the chemical does not change the sound speed SOS more than approximately 100 meters per second and provided the fluid all...

Страница 4: ...must not be cut or modified Note that the Sonic Pro can accurately measure flow from either direction The SPU can be mounted on a wall or on a horizontal or vertical run of pipe Although the Sonic Pro...

Страница 5: ...is required on downward flows to ensure a full pipe See the minimum straight length of pipe requirement chart above Related piping must be independently supported The meter should not be allowed to s...

Страница 6: ...d tight cable gland connectors for cable diameter from 200 to 394 inches 5 1 to 10 0 mm Two liquid tight cable gland connectors cable for diameters from 118 to 255 inches 3 0 to 6 5 mm One communicati...

Страница 7: ...ector T2 1 2 Positive Negative Type Open collector w internal 1 K pull up to 5V Can be pulled up to 30V 10mA 3K pull up Duty Cycle 50 5 Frequency Range 0 1000 Hz Resolution 1 Hz Accuracy 0 5 F S PADDL...

Страница 8: ...allowable SOS Speed Of Sound error set point has been exceeded FAULT 21 The configuration data is not valid Flow Direction Total Units U S Gallons Min 105 1482 25 05 469 U S Gallons 0 28 Transducer S...

Страница 9: ...he value Press ENTER to confirm the modifications and return to the menu heading Press ESC to cancel the modifications and return to the menu heading 5 3 2 Selecting Optional Items Press up arrow p or...

Страница 10: ...use your inlet outlet pipe material 10 Fluid Type Select WATER or CUSTOM 11 Fluid SOS If WATER is selected it is not necessary to input a fluid SOS If CUSTOM fluid type is selected the Speed of Sound...

Страница 11: ...e factory set inside the pipe fitting and cannot be moved Select the mount method that is shown on the Calibration Detail label affixed to the pipe fitting Transducer Model I C J Mount Method W V Cabl...

Страница 12: ...ings Direction Zero A B Scaling A B Enter Value Sign A B Zero Value A B Positive B A A B Enter Value Zero B A Scaling B A Enter Value Sign B A Zero Value B A Enter Value 0 975 0 455 Negative Positive...

Страница 13: ...n the acceptable range and there are not too many particles or other sound blocking or reflecting contaminants in the fluid which can inhibit the sound beam The target Fluid SOS value can be adjusted...

Страница 14: ...els Oil Cubic Feet Acre Feet Imperial Gallons Cubic Meters Liters Milliliters FR Custom V Gal Fl Total Decimal 0 Enter Value Flow Average s 0 Enter Value Enable Tot Clear Yes No Low Fl Cut Off 0 Enter...

Страница 15: ...into any Tot Set Point 1 2 3 4 or 5 a new log will be generated when the total accumulated flow value is equal to the configured value To access the log entries you must copy the logs onto a USB flash...

Страница 16: ...ters Milliliters TOT Custom V Gal Fl Total Decimal 0 Enter Value Flow Average s 0 Enter Value Enable Tot Clear Yes No Low Fl Cut Off 0 Enter Value High Fl Cut Off 999 Enter Value Scaling Off set 1 000...

Страница 17: ...Off value totalizing will still occur 6 3 2 6 High Flow Rate Cut off Setting High Fl Cut Off 999 Enter Value Scaling Off Set is a multiplier used to correct for flow inaccuracies All flow rate values...

Страница 18: ...e meter was sleeping using the following formula Total flow display value T1 F1 F2 2 x N 1 Where T1 Last total before sleep F1 Last flow rate units per second before sleep F2 Flow rate average of the...

Страница 19: ...gh Release A 0 Enter Value Low Trigger A 0 Enter Value Low Release A 0 Enter Value Time s A 0 Enter Value Monitor Totalizer Batch Amt A 0 Enter Value Contact Timer s A 0 Enter Value Faults A Relay B M...

Страница 20: ...ue Rate at Max Curr 0 0000 Enter Value Max Analog O P 20 Enter Value 6 4 2 Pulse 0 1000 Hz Output Menu A digital pulse output signal can be programmed within the range of 0 1000 Hz pulses per second S...

Страница 21: ...ue Faults B None A None B Relay B Monitor Flow Rate High Trigger B 0 Enter Value High Release B 0 Enter Value Low Trigger B 0 Enter Value Low Release B 0 Enter Value Time s B 0 Enter Value None B 6 4...

Страница 22: ...Value Contact Timer s B 0 Enter Value 6 4 3 2 CC Assigned to Monitor FAULTS When in the Relay A or Relay B menu selecting and then exiting the FAULTS menu will assign that relay to energize when any...

Страница 23: ...unsigned char 8 Frequency output 45 Firmware Version unsigned char 8 8 ASCII characters A11 22 33 53 Log Entry unsigned char 86 Log Entry String Eg 2013 12 29 09 15 00 FR 0 0000 TL 0 00 Description P...

Страница 24: ...e meter can be re calibrated in the field by selecting Calibration and pressing the right arrow u or ENTER button The pipe must be full of fluid and there must be no movement of the fluid in the pipe...

Страница 25: ...Save Config function is possible at the main menu Global Config Password 1234 Enter Value Change Password Change Password Old Pass 1234 OK CANCEL NEW Pass 5678 OK Enter master password 3408 to clear a...

Страница 26: ...me Units Independently configurable Rate and Total display units in U S Gallons ounces barrels US liquid barrels US oil cubic ft acre ft Imperial British gallons liter cubic meter or user defined cust...

Страница 27: ...ipe fitting transducer no transducer cables Standard 4 20mA and High Speed Pulse output only Without power supply customer supplies 15 30 VDC 0 25 ft cable length with field replaceable liquid tight c...

Страница 28: ...03 5 41 1427 10 50 1447 20 68 1481 30 86 1507 40 104 1526 50 122 1541 60 140 1552 70 158 1555 80 176 1555 90 194 1550 100 212 1543 Water Sound Speeds 7 2 Sound speed data Page 27 Sonic Pro Industries...

Страница 29: ...in 18 39cm 5 90in 14 97cm 74in 1 88cm 2 75in 6 99cm 7 24in 18 39cm 5 83in 14 80cm 55in 1 39cm 2 75in 6 99cm Sonic Pro Inline Pipe Fittings Pipe Size 2 1 5 1 75 5 Pipe Size OL OW A B C 2 7 47in 18 97cm...

Страница 30: ...ers TOT Custom V Gal Fl Total Decimal 0 Enter Value Flow Average s 0 Enter Value Enable Tot Clear Yes No Low Fl Cut Off 0 Enter Value High Fl Cut Off 999 Enter Value Scaling Off set 1 0000 Enter Value...

Страница 31: ...Enter Value Time s B 0 Enter Value Monitor Totalizer Batch Amt B 0 Enter Value Contact Timer s B 0 Enter Value Faults B Clock CLOCK SET 2013 07 24 14 31 OK CANCEL Calibration Clear Cal Value None A N...

Страница 32: ...kmanship for 24 months from date of factory shipment WARRANTY COVERAGE IS LIMITED TO REPAIR OR REPLACEMENT OF THE DEFECTIVE FLOWMETER ONLY UNDER NO CIRCUMSTANCES SHALL BLUE WHITE BE LIABLE FOR ANY CON...

Отзывы: