Sonic-Pro
Byte Bit
Type
No. of Bytes
1
0 Contact Closure 1
0: CC OFF, 1:CC ON
1 Contact Closure 2
0: CC OFF, 1:CC ON
2 Reserved
3 Reserved
1
4 Reserved
5 Reserved
6 Reserved
7 Reserved
2
0 Reserved
1 Reserved
2 Reserved
3 Reserved
1
4 Reserved
5 Reserved
6 Reserved
7 Reserved
3
Flow Rate
double
8
Current flow rate value.
11
Totalizer
double
8
Current totalizer value.
19
Fault Number Table
char
6
Fault number table upto six faults.
25
Speed of Sound
unsigned long
8
Current SOS value.
33
Goodness Of Meas.
unsigned char
1
Current GOM - 1 to 4.
34
Reserved
unsigned char
1
35
4 - 20mA Flow
unsigned char
1
4 to 20mA current output
36
Reserved
unsigned char
1
37
Flow Frequency
unsigned char
8
Frequency output
45
Firmware Version
unsigned char
8
8 ASCII characters. A11.22.33
53
Log Entry
unsigned char
86
Log Entry String
Eg: 2013/12/29 09:15:00 FR 0.0000 TL 0.00
Description
Page 22
Sonic-Pro
6.4.4
Anybus
Comm.
Menu
There are five different
Anybus
communications modules that can be installed in the S4
meter. Each optional module uses a different communications protocol.
6.4.3.1
CC Assigned to
Monitor Totalizer
When in the
Relay A
or
Relay B
menu, selecting and then exiting the
Monitor Totalizer
menu will assigned that relay to monitor the accumulated to flow value. The following
functions are possible:
!
Set a
Batch Amount
total flow value which when reached, will energize the relay.
!
Set the
Contact Timer(s)
for the number of seconds (0-999) that the relay will remain
energized.
When either of the relays are energized, the display back-light will turn blue.
Monitor Totalizer
Batch Amt. B
0
Enter Value
Contact Timer(s) B
0
Enter Value
6.4.3.2
CC Assigned to
Monitor FAULTS
When in the
Relay A
or
Relay B
menu, selecting and then exiting the
FAULTS
menu will
assign that relay to energize when any of the following fault conditions exist.
Ÿ
FAULT 11 -
Transducers are not connected or there is no fluid in the pipe.
Ÿ
FAULT 12 -
The allowable SOS (Speed Of Sound) error set-point has been exceeded.
Ÿ
FAULT 21 -
The configuration data is not valid.
The display back-light will turn red when there is a FAULT condition.
Faults B
Protocol
Anybus Communications Options
Profibus DPV
DB9F
Modbus RTU
Modbus TCP
Industrial Ethernet/IP
Profinet IO
Up to 12 Mbit/s
RJ45
10/100 Mbit/s full/half duplex
Network Connector
Baud Rate
DB9F
RJ45
RJ45
Up to 12 Mbit/s
10/100 Mbit/s full/half duplex
100 Mbit/s full duplex
Anybus
Type
Modbus RTU
Profibus DPV1
Modbus TCP
Ethernet
Profinet
None
Address
Modbus RTU
Profibus DPV1
Modbus TCP
Ethernet
Profinet
None
0
Enter Value
0
Enter Value
IP SET
192.168.234.123
OK
CANCEL
IP SET
192.168.234.123
OK
CANCEL
IP SET
192.168.234.123
OK
CANCEL
Select the module being used and enter the
Port Address
(for Profibus DPV or Modbus RTU
modules) or the
IP ADDRESS
( for Modbus TCP, Industrial Ethernet/IP or Profinet IO
modules.
Use the following Anybus mapping structure to communicate with the module and monitor the
flowmeter. There are no send commands available.
Optional Anybus
Communications
Module
Communications
Cable Grommet
Industries, Ltd.
Industries, Ltd.
ProSeries
by Blue-White Ind.
d
Industries, Ltd.
Industries, Ltd.
ProSeries
by Blue-White Ind.
d