6.5
Configure the
Clock
In the
Clock menu,
use the right arrow
u
or left arrow
t
to highlight the Year, Month, Day,
hour, or minute. Change the highlighted value using the up arrow
p
or down arrow
q
button.
To sve the entries, highlight
OK
and press
ENTER.
The clock is powered by a supercapacitor, which is continuously charging while the meter is
powered, rather than a battery. It never has to be replaced.
Clock
CLOCK SET
2013/07/24
14:31
OK
CANCEL
6.6
Zero Flow
Calibration
The zero calibration data can be stored for one flow direction only. If the
Pipe Fitting
and
SPU
was shipped from the factory as a single model number, the zero flow
Calibration
required to link the SPU and the Pipe Fitting was performed at the factory for the A --> B flow
direction. No further calibration is necessary. If the flow direction is from A <--- B or if a new
Ultrasonic Inline Pipe Fitting
is used, re-calibration may be necessary to achieve high
accuracy.
The meter can be re-calibrated in the field by selecting
Calibration
and pressing the right
arrow
u
or
ENTER
button. The pipe must be full of fluid and there must be no movement of
the fluid in the pipe during the calibration process.
Note that performing a
Zero Flow
Calibration
does not affect the Flow Direction
configuration settings shown on the Calibration Detail Label:
Zero
and
Zero +/-
variables:
transducer/Flow Direction/Settings/A -> B/
Calibration
Clear Cal. Value
CALIBRATION
CANCEL
Yes
No
Calibration
6.7
Global
Configuration
In the
Global Config.
menu, the user can configure a password, restore the factory default
configuration data, save and restore configuration data to a USB thumb drive, and update or
view the current firmware version.
6.7.1
Password
The S4 is shipped from the factory with the default password 0000. If a new password is not
configured, the meter will allow saving changes to the configuration at the main menu.
Configuration
Run
Save Config
A user defined four digit password can be entered to replace 0000.
Change Password
Change Password
New Pass.:
1234
CANCEL
Confirm Pass.: 1234
Once entered, the user defined password can be changed to any four digit number.
Once a new password has been configured, it must be entered to allow saving any changes
made to the configuration data. Once entered, the
Save Config
function is possible at the
main menu.
Global Config.
Password
1234
Enter Value
Change Password
Change Password
Old Pass.:
1234
OK
CANCEL
NEW Pass.:
5678
OK
Enter master password 3408 to clear any stored password.
6.7.2
Save/Restore
Config
The S4 configuration settings can be save and restored using a USB flash drive.
Save Conf. To USB
USB Drive Found!
Config. Copied To USB
Save Conf. To USB
OK
Restore USB Conf.
Config. File Found.
Erasing Config File..
Restore USB Conf.
Restored Config.
OK
6.7.3
Firmware
Update
The S4 firmware can be upgraded to the latest version. Download from
www.blue-white.com
to a USB flash drive.
Configuration data will not be erased.
Global Config.
Password
0
Enter Value
Firmware Update
Change Password
Change Password
Old Pass.:
0000
OK
CANCEL
NEW Pass.:
0000
Save Conf. To USB
USB Drive Found!
Config. Copied To USB
Save Conf. To USB
OK
Restore USB Conf.
Config. File Found.
Erasing Config File..
Restore USB Conf.
Restored Config.
OK
USB Drive Found.
Press ESC to upgrade
OK
Firmware Upgrade
Firmware Update
USB Drive Found.
Press ESC to upgrade
OK
Firmware Upgrade
Industries, Ltd.
Industries, Ltd.
ProSeries
by Blue-White Ind.
d
Industries, Ltd.
Industries, Ltd.
ProSeries
by Blue-White Ind.
d