8
Installation
7. Components
having
adjustments
protected (e.g. paint sealed) by manufacturer are only to be
adjusted by an authorised service agent. They are not to be adjusted by the installation person.
8.
The unit should be mounted under an extraction hood in compliance with all local regulations.
If the unit is not mounted under an extraction hood, the installer must ensure that all
regulations are met and that there is an unobstructed minimum distance of 750mm from top
surface of unit to ceiling, which must be of non-combustible material.
NOTE: Do not obstruct or block appliances flue. Never directly connect a ventilation system to
appliance flue outlet.
Clearances
NOTE: Only non-combustible materials can be used in close proximity to this appliance.
*
We recommend allowing a clearance of 100mm on either side of appliance to allow access to side
panels for servicing purposes.
**
Using wall mounting accessories provided with this appliance.
*** Top clearances can be reduced where local fire protection system is provided, if allowed by local
regulations.
Combustible Surface
Non-Combustible Surface
Left / Right Hand side
100mm
25mm (*)
Rear 50mm
30mm
(**)
Top Clearance to:
- Extraction Hood
200mm
750mm
- Ceiling (***)
- Grease Arresting Filter (***)
400mm
Australia / New Zealand