10
Installation
Gas Connection
NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED SERVICE PERSON.
1.
Blue Seal Salamanders do not require an electrical connection, as they function totally on gas supply
only.
2.
It is essential that gas supply is correct for Salamander being installed and that adequate supply
pressure and volume are available. The following checks should be made before installation:-
a. Gas Type appliance has been
supplied for, is shown on a
coloured sticker located above gas
connection and on rating plate.
Check that this is correct for gas
supply appliance is being installed
for. Gas conversion procedure is
detailed in this manual.
b. Supply Pressure required for this
appliance is shown in Specifica-
tions section of this
manual. Check gas supply to
ensure adequate supply pressure
exists.
c. Input Rate of this appliance is shown on Rating Plate and in Specifications section of this
manual. Input rate should be checked against available supply line capacity. Particular note
should be taken if salamander is being added to an existing installation.
NOTE: It is important that adequately sized piping runs directly to connection joint on appliance
with as few tees and elbows as possible to give maximum supply volume.
3.
Fit gas regulator supplied, into gas supply line as close to appliance as possible.
NOTE: Gas pressure regulator provided with this appliance is convertible between Natural Gas and
LPG as per ‘Gas Conversion Section’ in this manual.
Ensure regulator is converted to correct gas type that appliance will operate on.
Regulator outlet pressure is fixed ex-factory for gas type that regulator is converted to and
it is NOT to be adjusted.
Regulator connections are
1
/
2
" BSP female.
Connection to appliance is
1
/
2
" BSP male.
(Refer to Specifications section for gas supply location dimensions).
NOTE: A Manual Isolation Valve must be fitted to the individual appliance supply line.
4.
Correctly locate appliance into its final operating position.
5.
Connect gas supply to appliance. A suitable jointing compound which resists breakdown action of
LPG must be used on every gas line connection, unless compression fittings are used.
6.
Check all gas connections for leakages using soapy water or other gas detecting equipment.
Fig 5
Rating Plate
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.
Warning