7
Installation
Installation Requirements
NOTE: It is most important that this salamander is installed correctly and that operation is correct
before use. Installation shall comply with local gas, health and safety requirements.
Blue Seal Salamanders are designed to provide years of satisfactory service, and correct installation is
essential to achieve the best performance, efficiency and trouble-free operation.
This appliance must be installed in accordance with National installation codes and in addition, in
accordance with relevant National / Local codes covering gas and fire safety.
Australia / New Zealand:
- AS/NZS5601 - Gas Installations.
United Kingdom:
- Gas Safety (Installation & Use) Regulations 1998.
- BS6173
- Installation of Catering Appliances.
- BS5440
- 1 & 2 Installation Flueing & Ventilation.
Ireland:
- IS 820
- Non - Domestic Gas Installations.
Installations must be carried out by qualified service persons only. Failure to install
equipment to the relevant codes and manufacturer’s specifications shown in this section will
void the warranty.
Components having adjustments protected (e.g. paint sealed) by the manufacturer are only
to be adjusted by an qualified service person. They are not to be adjusted by the installation
person.
Unpacking
Remove all packaging and transit protection from appliance including all protective plastic coating
from exterior stainless steel panels.
Check equipment and parts for damage. Report any damage immediately to carrier and distributor.
Report any deficiencies to distributor who supplied appliance.
Check available gas supply is correct to as shown on rating plate located on front bottom corner of
right hand side panel.
Check the following parts have been supplied with appliance:
Location
1.
Installation must allow for sufficient flow of fresh air for combustion air supply.
2.
Installation must include adequate ventilation means, to prevent dangerous build up of combustion
products.
3.
This appliance must be mounted onto a non-combustible wall or tailored stand, using rear wall
bracket and spacing screws provided.
4.
Combustible walls must not protrude past front of appliance.
5.
This appliance must not be mounted on a combustible surface or metal surface, as radiated heat will
cause these surfaces to become extremely hot.
6.
Caution should be taken as intense heat is emitted at bottom front of appliance.
1 x Salamander Rack.
1 x Wall Mounting Bracket, including;
1 x Trough Tray.
- 2 x 25mm Black Plastic Spacers.
1 x Gas Regulator.
- 2 x
3
/
8
” Bolts / Nuts.
1 x Alternate Gas Conversion Kit.
Combustion Air Requirements:
Natural Gas 9
m
3
/hr
LP Gas / Butane 9
m
3
/hr
Town Gas 9
m
3
/hr
Содержание G91
Страница 24: ......