26
- UK Only
Appliance Classification
Category:
II
2H3P
(20, 30 / 37).
Flue Type:
A
1.
*
The burner operating pressure is to be measured at the manifold test point with two
burners operating at the ‘High’ setting. The operating pressure is ex-factory set, through the
appliance regulator and is not to be adjusted, apart from when carrying out gas conversion, if
required. (Refer to the ‘Gas Conversion’ section for details).
Gas Conversion and Specifications
Natural. Gas
(G20)
Propane
(G31)
Open Burner
Main Burner Injectors
Ø 2.30 mm
Ø 1.40 mm
Pilot Burner ('PF' Models Only)
0.30
0.20
Griddle
Main Burner
Ø 2.10 mm
Ø 1.30 mm
Pilot Burner
0.35
0.23
Main Burner
Ø 2.40 mm
Ø 1.40 mm
Pilot Burner
0.35
0.23
Low Fire
Ø 0.90 mm
Ø 0.55 mm
Supply Pressure
20 mbar
30 / 37 mbar
Operating Pressure
9.5 mbar (*)
26 mbar (*)
Gas Regulator Cap Screw
Oven
Burner Aeration Setting
Fully open
10 mm