9
NOTE: The gas pressure regulator provided with this appliance is convertible between Natural Gas
and LPG as per the ‘Gas Conversion Section’ in this manual.
Ensure the regulator is converted to the correct gas type that the appliance will operate on.
The regulator outlet pressure is fixed ex-factory for the gas type that the
regulator is converted to and it is NOT to be adjusted.
The regulator connections are
3
/
4
" BSP female.
The connection to the appliance is
3
/
4
" BSP male.
(Refer to the “Specifications” section for the gas supply location dimensions).
NOTE: A Manual Isolation Valve must be fitted to the individual appliance supply line.
4.
Correctly locate the appliance into its final operating position and using a spirit level, adjust the legs
so that the appliance is level and at the correct height.
5.
Connect the gas supply to the appliance. A suitable joining compound which resists the breakdown
action of LPG must be used on every gas line connection, unless compression fittings are used.
6.
Check all gas connections for leakages using soapy water or other gas detecting equipment.
7.
Check that the gas operating pressure is as shown in the ‘Specifications’ section.
NOTE: The operating pressure is to be measured at the
manifold pressure test point and with two burners
operating at the “High Flame” setting.
8.
Turn off the mains gas supply and bleed the gas out of
the appliance gas lines.
9.
Turn on the gas supply and the appliance.
10. Verify the operating pressure remains correct.
Commissioning
1.
Before leaving the new installation;
a. Check the following functions in accordance with the operating instructions specified in the
‘Operation’ section of this manual.
•
Lighting the Griddle.
•
Light the Open Burners. (F - Flame Failure Option).
•
Light the Open Burners. (PF - Pilot and Flame Failure Option).
•
Check the Low Fire burner operation.
•
Oven Pilot Ignition.
•
Oven Main Burner / Thermostat.
•
Turning the Oven to ‘Stand-By’ Mode.
•
Oven ‘Shut Down’.
b. Ensure that the operator has been instructed in the areas of correct lighting, operation, and
shutdown procedure for the appliance.
2.
This manual must be kept by the owner for future reference, and a record of
Date of Purchase,
Date of Installation
and
Serial Number of Unit
recorded and kept with this manual.
(These
details can be found on the Rating Plate attached to the bottom right hand corner of the
bottom sill. Refer to the ‘Gas Connection’ section)
.
NOTE: If for some reason it is not possible to get the appliance to operate correctly, shut off the
gas supply and contact the supplier of this appliance.
Installation
Fig 2
Manifold
Pressure Test
Point
WARNING:
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.
Содержание Evolution G504
Страница 7: ...5 Dimensions G504 G504D G504C G504B ...
Страница 8: ...6 Dimensions G528 G528D G528C G528B G528A ...
Страница 31: ...29 ...