4
Specifications
- CE Only
Appliance Classification
Category:
II
2H3P
(20, 30 / 37).
Flue Type:
A
1.
*
The burner operating pressure is to be measured at the manifold test point with two
burners operating at full setting. The operating pressure is ex-factory set, through the
appliance regulator and not to be adjusted, apart from when carrying out gas conversion, if
required. (Refer to the ‘Gas Conversion’ section for details).
Gas Connection
Gas supply connection point is located at the rear of the appliance, approximately 130 mm from the
right hand side, 35 mm from the rear and 655 mm from the floor and is reached from beneath the
appliance. (Refer to the ‘Dimensions’ section).
Connection is ¾" BSP male thread.
Natural Gas (G20)
Propane (G31)
Open Burner
(each)
Griddle
(each 300mm section)
Oven
Open Burner
(each)
Griddle
(each 300mm section)
Oven
Heat Input
(nett)
Nominal
6.5 kW
5.5 kW
6.5 kW
6.5 kW
5.5 kW
6.0 kW
Reduced
1.75 kW
1.85 kW
1.1 kW
1.75 kW
1.95 kW
1.05 kW
Gas Rate
(nett)
Nominal
0.69 m
3
/hr
0.58 m
3
/hr
0.69 m
3
/hr
0.51 kg/hr
0.43 kg/hr
0.47 kg/hr
Reduced
0.19 m
3
/hr
0.20 m
3
/hr
0.12 m
3
/hr
0.14 kg/hr
0.15 kg/hr
0.09 kg/hr
Supply Pressure
20 mbar
30 / 37 mbar
Burner Operating
Pressure
9.5 mbar (*)
26 mbar (*)
Gas Connection
3
/
4
” B.S.P. Male