rSt
” means (reset): This option enables you to reset the meter indication to the factory setting of 4,500 hours.
This selection is confirmed if the meter indication and “rSt” on the display blink alternately. If you hold down the switch (R) for 5 seconds,
after which the meter indication 4500 will be displayed, and then release it, the time meter will start counting down from the 4,500 hour
value. This selection is used if, for example, you have replaced the lamp, or if you have modified the meter indication yourself and you want
to return it to the factory settings.
- “
UP
” means (up): This option enables you to increase the meter indication to the desired hour indication.
This selection is confirmed if the selected user setting ”UP” and the meter indication on the display blink alternately. Following this, press the
switch (R) down for 5 seconds. After 5 seconds, the display will only indicate “UP”. You can then release the switch.
By briefly pressing the switch , the counter value can now be increased in steps of 500 hours from the value of 4500 up to a maximum value of
9999. The increased value and “UP” will blink alternately on the display.
After you have selected the desired hour indication, wait for 10 seconds. After 10 seconds, the selected hour indication will be displayed and
the timer will start counting down.
If you make a mistake while increasing the meter indication, it is possible to reset the counter to 4500 by keeping the switch pressed down for
5 seconds. The counter value will then be reset to 4500, and a new value can be set.
- “
dn
” means (down): This option enables you to decrease the meter indication to the desired hour indication.
This selection is confirmed if the selected user setting ”dn” and the meter indication on the display blink alternately. Following this, press the
switch (R) down for 5 seconds. After 5 seconds, the display will only indicate “dn”. You can then release the switch.
By briefly pressing the switch , the counter value can now be decreased in steps of 500 hours from the value of 4500 down to a minimum
value of 0000. The decreased value and “dn” will blink alternately on the display.
Once you have selected the desired hour indication, wait for 10 seconds. After 10 seconds, the selected hour indication will be displayed and
the timer will start counting down.
If you make a mistake while decreasing the meter indication, it is possible to reset the counter to 4500 by keeping the switch pressed down
for 5 seconds. The counter value will then be reset to 4500, and a new value can be set.
The time meter will indicate in the following manner that the lamp must be replaced:
- From hour position 0672; the display will blink every second. The lamp is to be replaced in 4 weeks’ time.
- From hour position 0336; the display will blink every half second; The lamp is to be replaced in 2 weeks’ time.
- From hour position 0168; the display will blink every ¼ second; The lamp is to be replaced in 1 week’s time.
- At an hour position of 0000; the digits will blink continuously, and the meter will not continue to count down. The lamp must be replaced.
Dismantling / Maintenance
Always switch off the power supply during maintenance/dismantling of the device.
The device must be cleaned twice a year. If there is an increase in algae and/or scale, the quartz glass tube (
M
) in which the lamp is positioned
must be cleaned. The special lamp must be replaced at the latest after 9,000 operating hours. The stainless steel interior can be cleaned with
a soft brush.
1 Unscrew the three-part couplings (
I
) and drain the water from the device.
2 Unscrew the screw cap (
N
) and disconnect the lamp (
K
) from the lamp holder (
L
). Remove the lamp from the quartz glass and, if necessary,
replace the special lamp (
K
). As these parts are very fragile, caution is essential.
3 Carefully remove the quartz glass (
M
) using a large, flat screwdriver (
see drawing 3
). Never use force!
4 Clean the quartz glass with a suitable agent. Always use a soft cloth to clean the glass in order to prevent scratches.
5 Pay attention to the correct position of the 3 sealing rings (
P
) when replacing the quartz glass in the housing, and carefully introduce the
end of the quartz glass into the inlet(
Q
) (
see drawing 4
). Never use force!
6 Carefully replace the lamp in the quartz glass and connect the lamp (
K
) to the lamp holder (
L
). Screw the screw cap (
N
) onto the housing again.
7 The electrical unit of the device is situated in the display box (
S
) on the device. This display box is glued and cannot be opened. If the
electrical unit or the display is replaced, the entire box must be unscrewed and the wiring must be disconnected from the device (
see drawing 1
).
Unscrew the screw top (
N
) and carefully remove the lamp holder from the lamp. Any loose parts, i.e. of the earth etc., must be carefully
retained, as they are not supplied with a new housing or electrical unit. In case of any doubt with regard to the connection, consult a
recognised fitter.
Содержание UV-C Timer
Страница 1: ...1 The easy and friendly way to disinfect your pool Blue Lagoon UV C Timer 40 000 75 000 ...
Страница 2: ...2 1 2 3 4 N M K R U J Q S O P P I L T ...
Страница 75: ...75 1 2 3 4 N M K R U J Q S O P P I L T ...
Страница 77: ...1 The easy and friendly way to disinfect your pool UV C TIMER 150 000 130 WATT AMALGAM ...
Страница 78: ...2 1 2 3 4 N M K R U J Q S O P P I L T V W X ...
Страница 143: ...67 1 2 3 4 N M K R U J Q S O P P I L T V W X ...