24
25
(1) Cleaning Procedure
3.4 [BLUI-250A]Interior Cleaning & Sanitizing Procedure
1) Turn off the ice maker. If ices are being made, wait for cycle completion and then turn off the ice maker.
2) Remove all remaining ices in the storage.
3) Prepare 12 liters of cleaning solution by diluting 1 pack(56.7g/2 Oz) of Kay-Delimer with 4 liters of warm water.
4) Contact the distributor of ice maker to purchase cleaning solution [Kay - Delimer]
5) Press “WASH” button.
6) Remaining water in the storage is drained and “drn” appears on the control board.
7) Once drainage is completed, “Add” will appear on the control board.
8) Pour 6 liters of cleaning solution from procedure 3) into the water tank.
(The next operation is automatically performed after 60 seconds)
9) “Crn” will appear on the control board after a minute.
10) The water pump drains the water after 30 minutes of operation.
11) After drainage, water will be supplied for 3 minutes.
12) The water pump operates for 5 minutes to remove remaining cleaning solution.
13) The water is drained after 5 minutes washing procedure.
14) The ice maker repeats step 11 to step 13 three times for 30 minutes.
15) Water will be supplied for 3 minutes.
16) Once water supply is completed, appears on the control board and Power Turns off.
17) Disassemble hose and water tank referring to step6 ~ 8 on 250 Product Disassembly
(All parts of ice maker has to be disassembled and cleaned referring to step 1 ~ 10 on 250 Product
Disassembly at least once every six months.)
18) Wash disassembled parts with 6 liters of cleaning solution from 3). Only use nylon brush (Not wire brush),
sponge and soft cloth to brush the parts. (Dishwashing liquid also can be used while the cleaning procedure)
19) Wash storage out with clean water and dry the storage.
A display is composed of 3 buttons and 5
status lights and 3 7-segment.
Fig 5
Guide Ice
Bolt
Storage bin
Drain pipe
Water Tank