Chapter 2: First-Time Configuration
23
Figure 2-9: Initial Setup—Page One
5
On page 2, enter a console username and a console and enable password. A default username (
admin
)
is already in place—change it for stronger security.
Welcome to the ProxySG Appliance Setup Console
--------------------- (page 1 of 5) --------------------
Press <ESC> at any time to return to the main menu
DIRECTIONS:
This setup console is used to assign IP addresses to the ProxySG
Appliance. After assigning the IP addresses you can connect to the
command line interface or Web interface to perform additional
management tasks.
If you have a pass through card, you can configure it by using the
bridge name passthru-<slot number>. For example if the pass through
card is at slot 2, the bridge name would be passthru-2.
In order to create a new bridge, you would have to
1. assign a name to the bridge
2. associate one or more interfaces to the bridge
Enter bridge name to configure [passthru-0]:
IP address [0.0.0.0]:
10.25.36.47
IP subnet mask [255.255.255.0]:
255.255.255.0
IP gateway [0.0.0.0]:
10.25.36.1
DNS server [0.0.0.0]:
101.52.23.100
You have entered the following IP addresses:
IP address: 10.25.36.47
IP subnet mask: 255.255.255.0
IP gateway: 10.25.36.1
DNS server: 101.52.23.101
Would you like to change any of them? Y/N [No]