G5 Weighing Instrument
7-1
7. Maintenance
General
This chapter describes the maintenance functions when handled from the local display.
The Maintenance menu includes a number functions used for diagnostics,
maintenance and program upgrade purposes. The Maintenance menu is found under
the Main menu.
The Fieldbus diagnostics shows
data input or output in hexadecimal
format. It can be used to compare
with how data is shown in the PLC
to trouble shoot byte swap,
alignment etc.
F1 (Previous) and F2 (Next) are
used to scroll within the instrument
output data. A screen will show 40
bytes and pressing F1/F2 will scroll
to next/previous 40 bytes of data.
F3 (In or Out) will toggle between
input and output data.
Press Escape button to leave the
menu.
The first line of text shows which
type of Fieldbus that is usd, the
instrument fieldbus address and the
actual status of the connection.
Instrument input data (from master)
Instrument output data (to master)