G5 Weighing Instrument
5-7
Scale Status
Bits set to 1 in this register have the following meaning:
Bit no Function
Comment
0
Not used
Not used in the fieldbus interface
1
Not used
Not used in the fieldbus interface
2
Not used
Not used in the fieldbus interface
3
Good zero (disp. weight)
4
Good zero Gross
5
Good zero Net
6
Net Mode
'1' = Net mode
‘0' = Gross mode
7
Motion
Unstable weight
8
Not used
9
Not used
10
Not used
11
Flow rate display
Flow rate is shown in the display.
12
Net weight > 6 digits
The net weight value is out of precision and
should normally not be used.
13
Gross weight > 6 digits
The gross weight value is out of precision and
should normally not be used.
14
Not used
15
Not used
Gross weight
The gross weight value consists of 4 bytes. The weight should
not
be read alone
because the status and error codes are stored in other registers. The weight is only
valid when the register ‘Scale Error code’ equals 00. Gross weight can be in integer
format or floating point format depending on the setting. The number of decimals
used in the gross weight can be read in byte 88.
Net weight
The net weight value consists of 4 bytes. The weight should
not
be read alone
because the status and error codes are stored in other registers. The weight is only
valid when the register ‘Scale Error code’ equals 00. Net weight can be in integer
format or floating point format depending on the setting. The number of decimals
used in the net weight can be read in byte 88.