VENT CONNECTOR REMOVAL AND
INSTALLATION
The vent connector slide plate is shipped attached
to the insert, but may be removed and attached to
fl
ex vent for tight installations.
NOTE: The vent connector slide plate gasket
must not be damaged or removed. Ensure
that the gasket remains intact to prevent
fl
ue
leakage.
1. Feed the
fl
ex vent through the chimney from
above, leave approximately 3ft out the top and
tie o
ff
if necessary. Ensure the
fl
ex vent is
stretched as needed.
2. Unscrew the 1/4-20 bolt from the vent
connector slide plate
(Fig.2)
and remove to
attach to the
fl
ex vents WITH HOSE CLAMPS
as shown below:
3. Adjust the
fl
ex vent until the vent connector is at
the same height as the insert.
4. Slide the insert into place, guide the vent
connector slide plate into the guides on the top
of the insert.(
Fig.3
)
5. Refasten the vent connector plate to the
appliance using the front 1/4-20 bolt. (
Fig.4
)
6. At the top remove any excess slack in the
fl
ex
line, attach the vent termination, and seal with
fl
ashing as necessary.
Fig.2
Fig.3
Fig.4
INSTALLATION