180-CL2714.IPI v1.01
April 21, 2021
Page 13
Clarity CL2714 IPI
INSTALLATION PLANNING
The included label plate, shown below, must be permanently attached inside the cavity of the
fi
replace in a
visible location.
WARNING: This
fi
replace has been converted for use with a gas
fi
replace insert
only and cannot be used for burning wood or solid fuels unless all original
parts have been replaced, and the
fi
replace reapproved by the authority having
jurisdiction.
AVERTISSEMENT: Ce foyer a été converti
pour l’utiliser avec un encastrable au gaz et
ne peut pas être utilisé pour brûler du bois
ou d’autres combustibles solides, à moins
que toutes les pièces d’origine aient été
remplacées et que le foyer ait été approuvé à
nouveau par les autorités compétentes.
170-0166
W
Minimum
fi
replace dimensions /
Dimensions minimales du foyer
Minimum
fl
ue size /
Taille minimale de la cheminée
6” x 6” /
152mm x 152mm
Height / Hauteur
20” / 508 mm
Depth / Profondeur
15 1/2”/ 394 mm
Width (rear) / Largeur (arrière)
22” / 559 mm
Width (front) / Largeur (avant)
29 1/8” / 740 mm
• Cutting any sheet-metal parts of a steel solid fuel
burning
fi
replace, in which the gas
fi
replace insert is
to be installed, is prohibited.
• The
fi
replace
fl
ue damper can be fully blocked open
or removed for installation of the gas
fi
replace insert.
• The
fi
replace and
fi
replace chimney must be clean
and in good working order and constructed of non-
combustible materials.
• Chimney clean outs must
fi
t properly.
Check local
codes whether
a continuous
length is
required or if
certi
fi
ed joiner
kits may be
used.
Minimum 8 ft.
Maximum 36 ft.
Flashing
Co-linear DV vertical
termination cap
Air
Intake
Exhaust
Flue
FACTORY BUILT FIREPLACE OR ZERO CLEARANCE
FIREPLACE
• Ensure that there is a minimum base of sheet metal
below the unit upon installation along with supplied
levelling bolts.
• If the factory-built
fi
replace has no gas access
hole(s) provided, an access hole of 1.5” (37.5 mm)
or less may be drilled through the lower sides or
bottom of the
fi
rebox in a proper workmanship-like
manner. This access hole must be plugged with non-
combustible insulation after the gas supply line has
been installed.
• Refractory, glass doors, screen rails, screen mesh,
and log grates can be removed from the
fi
replace
before installing the gas
fi
replace insert.
• Smoke shelves, shields, and ba
ffl
es may be removed
if attached by mechanical fasteners.
• Trim panels or surrounds shall not seal ventilation
openings in the
fi
replace.
Massachusetts installations (Warning): This product must be installed by a licensed plumber or gas
fi
tter when
installed within the Commonwealth of Massachusetts. Other Massachusetts code requirements: Flexible
connector must not be longer than 36in., a shut o
ff
valve must be installed; only direct vent sealed combustion
products are approved for bedrooms/bathrooms. A carbon monoxide detector is required in all rooms
containing gas
fi
red direct vent appliances. The
fi
replace damper must be removed or welded in the open
position prior to installation of a
fi
replace insert.