180-CL2714.IPI v1.01
April 21, 2021
Page 6
Clarity CL2714 IPI
GENERAL INFORMATION
SPECIFICATIONS
MODEL
CL2714.IPI
Natural Gas (NG)
Propane (LP)
Manifold Pressure
3.8 in. w.c. (0.95kPa)
11.0 in. w.c. (2.74 kPa)
Min. Supply Pressure for
Purpose of Input Adjustment
7 in. w.c. (1.74 kPa)
13.0 in. w.c. (3.23 kPa)
Ori
fi
ce Size
DMS #41
DMS #53
Nominal Input Rating
24,682 BTU/hr, 7.23 kWh
24,956 BTU/hr, 9.31 kWh
Minimum Input Rating
12,893 BTU/hr, 3.78 kWh
12,982 BTU/hr, 3.80 kWh
Altitude
0 - 4,500 ft. (0 - 1372 m)
0 - 4,500 ft. (0 - 1372 m)
Primary Air Opening
1/16” (Minimum)
1/16” (Minimum)
Electrical Rating
120 V.A.C. System
120 V.A.C. System
HIGH ALTITUDE INSTALLATION
When installing this appliance beyond 4500 ft. (1372 m) above sea level, the appliance must be properly de-
rated and installed according to local codes, in the absence of local codes, with the current National Fuel Gas
Code, ANSI Z223.1/ NFPA 54, in the US or Installation Code, CSA-B149.1, in Canada.
INSTALLATION CODES
This appliance must be installed by a quali
fi
ed gas
appliance installer. This appliance is certi
fi
ed for installation
in a bedroom or a bedsitting room. This appliance is only
for use with the type of gas indicated on the rating plate and
may be installed in an aftermarket, permanently located,
manufactured (mobile) home where not prohibited by
local codes. This appliance is not convertible for use with
other gases, unless a certi
fi
ed kit is used. Only for direct
discharge without duct connection. This appliance must
be direct vented using listed and approved Simpson Dura-
Vent, Selkirk, Security or American Metal Products vent
components.
We recommend
that our gas hearth
products be installed
and serviced by
professionals who are
certi
fi
ed in the U.S. by
the National Fireplace
Institute (NFI) as NFI
Gas Specialists.
APPLIANCE CERTIFICATION
This appliance is tested and certi
fi
ed to the following US and Canadian gas appliance standards:
• ANSI Z21.88-2017 / CSA 2.33-2017 Vented Gas Fireplace Heaters,
• CAN/CGA-2.17-M91 (R2014) Gas-Fired Appliance for Use at High Altitudes
• CSA P.4.1-15 Testing Method for Measuring Annual Fireplace E
ffi
ciency
STEADY STATE EFFICIENCY
Natural Gas (NG)
Propane (LP)
Steady State E
ffi
ciency - High
E
ff
y
SS,H
66.87%
69.48%
Annual Fireplace E
ffi
ciency
FE
63.82%
64.63%