180-CL2714.IPI v1.01
April 21, 2021
Page 25
Clarity CL2714 IPI
885 PROFLAME VALVE
1
2
11
7
9
4
3
8
10
12
12
12
12
12
6
5-c
885 PROFLAME VALVE
1
ON-OFF solenoid EV1 terminals
2
ON-OFF solenoid EV2 terminals
3
Inlet pressure test point
4
Outlet pressure test point
5-c
Electrical pressure modulator device
6
Pressure modulator device terminal
7
Pilot adjusting screw
8
Pilot outlet
9
Gas inlet with protective seal
10
Gas outlet with protective seal
11
Ground connection
12
Mounting holes