When installed with a VB1000 blower cabinet mounted on either side, the APEX CBT becomes an
INDEPENDENT wood only furnace. The blower must have a minimum 900 cfm. capacity (1/3 hp.).
In this configuration the interlock limit is not used. Figure 23 shows the electrical connections, (use
only 1 limit switch).
INSTALLATION INSTRUCTIONS - WOOD ONLY
Fig. 23 ELECTRICAL CONNECTIONS INDEPENDENT WOOD
L4064R1027
INTERLOCK LIMIT
150 DEG F
L4064N1058
LIMIT MANUAL RESET /FAN
25O F (121 C)
Junction
Box
120VAC IN
120VAC Out to Blower
N
N
TRANS-
FORMER
WOOD THERMOSTAT
DAMPER
MOTOR
120V IN
24V OUT
Do NOT
Break Jumper
200F (93F)