22
7.1
Fault indicators
When a fault occurs, LED2(100%) + LED3(75%) + LED4(50%) will blink at the same time.
When a fault occurs, LED2(100%)/LED3(75%)/LED4(50%)will blink at the same time.
The panel below shows the status of charging of the batteries and a red light if a fault occurs.
SOC = State of charge is the level of charge of an electric battery relative to its capacity.
SOH = State of health will be 100% at the time of manufacture and will decrease over time and use.
Blinking
Frequency
Fault cause
Solution
1
The batteries are not connected, or
The battery voltage is too low
1) Check battery connection is correct.
2) Check charger connection is correct.
3) Check each battery is good.
2
Abnormal AC Power Input (Voltage)
1) Check AC input cord is connected between charger and
AC outlet.
2) Make sure AC plug is tightly inserted into AC outlet.
3
Charger High Temperature Protection 1) Charger shuts down and enters protection mode due to
charger/environmental temperature is too high. Please
place the charger in a well-ventilated environment.
2) Disconnect the charger and wait for 15-20mins before
reconnecting for charging.
4
Battery High Temperature Protection
1) Charger will reduce current and will even stop charging
to prevent the battery from overheating when battery
temperature exceeds the preset value.
2) When the battery temperature drops, the charger will
restart automatically.
5
Output Current is too large
Return to the factory for repairing.
6
Battery Voltage is too high
Check and assure that the correct output
battery voltage is connected.
3
2
1
4
Содержание BMS-220 ADB